linux/drivers/staging/nvec/nvec_power.c
<<
>>
Prefs
   1/*
   2 * nvec_power: power supply driver for a NVIDIA compliant embedded controller
   3 *
   4 * Copyright (C) 2011 The AC100 Kernel Team <ac100@lists.launchpad.net>
   5 *
   6 * Authors:  Ilya Petrov <ilya.muromec@gmail.com>
   7 *           Marc Dietrich <marvin24@gmx.de>
   8 *
   9 * This file is subject to the terms and conditions of the GNU General Public
  10 * License.  See the file "COPYING" in the main directory of this archive
  11 * for more details.
  12 *
  13 */
  14
  15#include <linux/module.h>
  16#include <linux/platform_device.h>
  17#include <linux/err.h>
  18#include <linux/power_supply.h>
  19#include <linux/slab.h>
  20#include <linux/workqueue.h>
  21#include <linux/delay.h>
  22
  23#include "nvec.h"
  24
  25#define GET_SYSTEM_STATUS 0x00
  26
  27struct nvec_power {
  28        struct notifier_block notifier;
  29        struct delayed_work poller;
  30        struct nvec_chip *nvec;
  31        int on;
  32        int bat_present;
  33        int bat_status;
  34        int bat_voltage_now;
  35        int bat_current_now;
  36        int bat_current_avg;
  37        int time_remain;
  38        int charge_full_design;
  39        int charge_last_full;
  40        int critical_capacity;
  41        int capacity_remain;
  42        int bat_temperature;
  43        int bat_cap;
  44        int bat_type_enum;
  45        char bat_manu[30];
  46        char bat_model[30];
  47        char bat_type[30];
  48};
  49
  50enum {
  51        SLOT_STATUS,
  52        VOLTAGE,
  53        TIME_REMAINING,
  54        CURRENT,
  55        AVERAGE_CURRENT,
  56        AVERAGING_TIME_INTERVAL,
  57        CAPACITY_REMAINING,
  58        LAST_FULL_CHARGE_CAPACITY,
  59        DESIGN_CAPACITY,
  60        CRITICAL_CAPACITY,
  61        TEMPERATURE,
  62        MANUFACTURER,
  63        MODEL,
  64        TYPE,
  65};
  66
  67enum {
  68        AC,
  69        BAT,
  70};
  71
  72struct bat_response {
  73        u8 event_type;
  74        u8 length;
  75        u8 sub_type;
  76        u8 status;
  77        /* payload */
  78        union {
  79                char plc[30];
  80                u16 plu;
  81                s16 pls;
  82        };
  83};
  84
  85static struct power_supply nvec_bat_psy;
  86static struct power_supply nvec_psy;
  87
  88static int nvec_power_notifier(struct notifier_block *nb,
  89                               unsigned long event_type, void *data)
  90{
  91        struct nvec_power *power =
  92            container_of(nb, struct nvec_power, notifier);
  93        struct bat_response *res = (struct bat_response *)data;
  94
  95        if (event_type != NVEC_SYS)
  96                return NOTIFY_DONE;
  97
  98        if (res->sub_type == 0) {
  99                if (power->on != res->plu) {
 100                        power->on = res->plu;
 101                        power_supply_changed(&nvec_psy);
 102                }
 103                return NOTIFY_STOP;
 104        }
 105        return NOTIFY_OK;
 106}
 107
 108static const int bat_init[] = {
 109        LAST_FULL_CHARGE_CAPACITY, DESIGN_CAPACITY, CRITICAL_CAPACITY,
 110        MANUFACTURER, MODEL, TYPE,
 111};
 112
 113static void get_bat_mfg_data(struct nvec_power *power)
 114{
 115        int i;
 116        char buf[] = { NVEC_BAT, SLOT_STATUS };
 117
 118        for (i = 0; i < ARRAY_SIZE(bat_init); i++) {
 119                buf[1] = bat_init[i];
 120                nvec_write_async(power->nvec, buf, 2);
 121        }
 122}
 123
 124static int nvec_power_bat_notifier(struct notifier_block *nb,
 125                                   unsigned long event_type, void *data)
 126{
 127        struct nvec_power *power =
 128            container_of(nb, struct nvec_power, notifier);
 129        struct bat_response *res = (struct bat_response *)data;
 130        int status_changed = 0;
 131
 132        if (event_type != NVEC_BAT)
 133                return NOTIFY_DONE;
 134
 135        switch (res->sub_type) {
 136        case SLOT_STATUS:
 137                if (res->plc[0] & 1) {
 138                        if (power->bat_present == 0) {
 139                                status_changed = 1;
 140                                get_bat_mfg_data(power);
 141                        }
 142
 143                        power->bat_present = 1;
 144
 145                        switch ((res->plc[0] >> 1) & 3) {
 146                        case 0:
 147                                power->bat_status =
 148                                    POWER_SUPPLY_STATUS_NOT_CHARGING;
 149                                break;
 150                        case 1:
 151                                power->bat_status =
 152                                    POWER_SUPPLY_STATUS_CHARGING;
 153                                break;
 154                        case 2:
 155                                power->bat_status =
 156                                    POWER_SUPPLY_STATUS_DISCHARGING;
 157                                break;
 158                        default:
 159                                power->bat_status = POWER_SUPPLY_STATUS_UNKNOWN;
 160                        }
 161                } else {
 162                        if (power->bat_present == 1)
 163                                status_changed = 1;
 164
 165                        power->bat_present = 0;
 166                        power->bat_status = POWER_SUPPLY_STATUS_UNKNOWN;
 167                }
 168                power->bat_cap = res->plc[1];
 169                if (status_changed)
 170                        power_supply_changed(&nvec_bat_psy);
 171                break;
 172        case VOLTAGE:
 173                power->bat_voltage_now = res->plu * 1000;
 174                break;
 175        case TIME_REMAINING:
 176                power->time_remain = res->plu * 3600;
 177                break;
 178        case CURRENT:
 179                power->bat_current_now = res->pls * 1000;
 180                break;
 181        case AVERAGE_CURRENT:
 182                power->bat_current_avg = res->pls * 1000;
 183                break;
 184        case CAPACITY_REMAINING:
 185                power->capacity_remain = res->plu * 1000;
 186                break;
 187        case LAST_FULL_CHARGE_CAPACITY:
 188                power->charge_last_full = res->plu * 1000;
 189                break;
 190        case DESIGN_CAPACITY:
 191                power->charge_full_design = res->plu * 1000;
 192                break;
 193        case CRITICAL_CAPACITY:
 194                power->critical_capacity = res->plu * 1000;
 195                break;
 196        case TEMPERATURE:
 197                power->bat_temperature = res->plu - 2732;
 198                break;
 199        case MANUFACTURER:
 200                memcpy(power->bat_manu, &res->plc, res->length - 2);
 201                power->bat_model[res->length - 2] = '\0';
 202                break;
 203        case MODEL:
 204                memcpy(power->bat_model, &res->plc, res->length - 2);
 205                power->bat_model[res->length - 2] = '\0';
 206                break;
 207        case TYPE:
 208                memcpy(power->bat_type, &res->plc, res->length - 2);
 209                power->bat_type[res->length - 2] = '\0';
 210                /* this differs a little from the spec
 211                   fill in more if you find some */
 212                if (!strncmp(power->bat_type, "Li", 30))
 213                        power->bat_type_enum = POWER_SUPPLY_TECHNOLOGY_LION;
 214                else
 215                        power->bat_type_enum = POWER_SUPPLY_TECHNOLOGY_UNKNOWN;
 216                break;
 217        default:
 218                return NOTIFY_STOP;
 219        }
 220
 221        return NOTIFY_STOP;
 222}
 223
 224static int nvec_power_get_property(struct power_supply *psy,
 225                                   enum power_supply_property psp,
 226                                   union power_supply_propval *val)
 227{
 228        struct nvec_power *power = dev_get_drvdata(psy->dev->parent);
 229        switch (psp) {
 230        case POWER_SUPPLY_PROP_ONLINE:
 231                val->intval = power->on;
 232                break;
 233        default:
 234                return -EINVAL;
 235        }
 236        return 0;
 237}
 238
 239static int nvec_battery_get_property(struct power_supply *psy,
 240                                     enum power_supply_property psp,
 241                                     union power_supply_propval *val)
 242{
 243        struct nvec_power *power = dev_get_drvdata(psy->dev->parent);
 244
 245        switch (psp) {
 246        case POWER_SUPPLY_PROP_STATUS:
 247                val->intval = power->bat_status;
 248                break;
 249        case POWER_SUPPLY_PROP_CAPACITY:
 250                val->intval = power->bat_cap;
 251                break;
 252        case POWER_SUPPLY_PROP_PRESENT:
 253                val->intval = power->bat_present;
 254                break;
 255        case POWER_SUPPLY_PROP_VOLTAGE_NOW:
 256                val->intval = power->bat_voltage_now;
 257                break;
 258        case POWER_SUPPLY_PROP_CURRENT_NOW:
 259                val->intval = power->bat_current_now;
 260                break;
 261        case POWER_SUPPLY_PROP_CURRENT_AVG:
 262                val->intval = power->bat_current_avg;
 263                break;
 264        case POWER_SUPPLY_PROP_TIME_TO_EMPTY_NOW:
 265                val->intval = power->time_remain;
 266                break;
 267        case POWER_SUPPLY_PROP_CHARGE_FULL_DESIGN:
 268                val->intval = power->charge_full_design;
 269                break;
 270        case POWER_SUPPLY_PROP_CHARGE_FULL:
 271                val->intval = power->charge_last_full;
 272                break;
 273        case POWER_SUPPLY_PROP_CHARGE_EMPTY:
 274                val->intval = power->critical_capacity;
 275                break;
 276        case POWER_SUPPLY_PROP_CHARGE_NOW:
 277                val->intval = power->capacity_remain;
 278                break;
 279        case POWER_SUPPLY_PROP_TEMP:
 280                val->intval = power->bat_temperature;
 281                break;
 282        case POWER_SUPPLY_PROP_MANUFACTURER:
 283                val->strval = power->bat_manu;
 284                break;
 285        case POWER_SUPPLY_PROP_MODEL_NAME:
 286                val->strval = power->bat_model;
 287                break;
 288        case POWER_SUPPLY_PROP_TECHNOLOGY:
 289                val->intval = power->bat_type_enum;
 290                break;
 291        default:
 292                return -EINVAL;
 293        }
 294        return 0;
 295}
 296
 297static enum power_supply_property nvec_power_props[] = {
 298        POWER_SUPPLY_PROP_ONLINE,
 299};
 300
 301static enum power_supply_property nvec_battery_props[] = {
 302        POWER_SUPPLY_PROP_STATUS,
 303        POWER_SUPPLY_PROP_PRESENT,
 304        POWER_SUPPLY_PROP_CAPACITY,
 305        POWER_SUPPLY_PROP_VOLTAGE_NOW,
 306        POWER_SUPPLY_PROP_CURRENT_NOW,
 307#ifdef EC_FULL_DIAG
 308        POWER_SUPPLY_PROP_CURRENT_AVG,
 309        POWER_SUPPLY_PROP_TEMP,
 310        POWER_SUPPLY_PROP_TIME_TO_EMPTY_NOW,
 311#endif
 312        POWER_SUPPLY_PROP_CHARGE_FULL_DESIGN,
 313        POWER_SUPPLY_PROP_CHARGE_FULL,
 314        POWER_SUPPLY_PROP_CHARGE_EMPTY,
 315        POWER_SUPPLY_PROP_CHARGE_NOW,
 316        POWER_SUPPLY_PROP_MANUFACTURER,
 317        POWER_SUPPLY_PROP_MODEL_NAME,
 318        POWER_SUPPLY_PROP_TECHNOLOGY,
 319};
 320
 321static char *nvec_power_supplied_to[] = {
 322        "battery",
 323};
 324
 325static struct power_supply nvec_bat_psy = {
 326        .name = "battery",
 327        .type = POWER_SUPPLY_TYPE_BATTERY,
 328        .properties = nvec_battery_props,
 329        .num_properties = ARRAY_SIZE(nvec_battery_props),
 330        .get_property = nvec_battery_get_property,
 331};
 332
 333static struct power_supply nvec_psy = {
 334        .name = "ac",
 335        .type = POWER_SUPPLY_TYPE_MAINS,
 336        .supplied_to = nvec_power_supplied_to,
 337        .num_supplicants = ARRAY_SIZE(nvec_power_supplied_to),
 338        .properties = nvec_power_props,
 339        .num_properties = ARRAY_SIZE(nvec_power_props),
 340        .get_property = nvec_power_get_property,
 341};
 342
 343static int counter;
 344static int const bat_iter[] = {
 345        SLOT_STATUS, VOLTAGE, CURRENT, CAPACITY_REMAINING,
 346#ifdef EC_FULL_DIAG
 347        AVERAGE_CURRENT, TEMPERATURE, TIME_REMAINING,
 348#endif
 349};
 350
 351static void nvec_power_poll(struct work_struct *work)
 352{
 353        char buf[] = { NVEC_SYS, GET_SYSTEM_STATUS };
 354        struct nvec_power *power = container_of(work, struct nvec_power,
 355                                                poller.work);
 356
 357        if (counter >= ARRAY_SIZE(bat_iter))
 358                counter = 0;
 359
 360/* AC status via sys req */
 361        nvec_write_async(power->nvec, buf, 2);
 362        msleep(100);
 363
 364/* select a battery request function via round robin
 365   doing it all at once seems to overload the power supply */
 366        buf[0] = NVEC_BAT;
 367        buf[1] = bat_iter[counter++];
 368        nvec_write_async(power->nvec, buf, 2);
 369
 370        schedule_delayed_work(to_delayed_work(work), msecs_to_jiffies(5000));
 371};
 372
 373static int nvec_power_probe(struct platform_device *pdev)
 374{
 375        struct power_supply *psy;
 376        struct nvec_power *power;
 377        struct nvec_chip *nvec = dev_get_drvdata(pdev->dev.parent);
 378
 379        power = devm_kzalloc(&pdev->dev, sizeof(struct nvec_power), GFP_NOWAIT);
 380        if (power == NULL)
 381                return -ENOMEM;
 382
 383        dev_set_drvdata(&pdev->dev, power);
 384        power->nvec = nvec;
 385
 386        switch (pdev->id) {
 387        case AC:
 388                psy = &nvec_psy;
 389
 390                power->notifier.notifier_call = nvec_power_notifier;
 391
 392                INIT_DELAYED_WORK(&power->poller, nvec_power_poll);
 393                schedule_delayed_work(&power->poller, msecs_to_jiffies(5000));
 394                break;
 395        case BAT:
 396                psy = &nvec_bat_psy;
 397
 398                power->notifier.notifier_call = nvec_power_bat_notifier;
 399                break;
 400        default:
 401                return -ENODEV;
 402        }
 403
 404        nvec_register_notifier(nvec, &power->notifier, NVEC_SYS);
 405
 406        if (pdev->id == BAT)
 407                get_bat_mfg_data(power);
 408
 409        return power_supply_register(&pdev->dev, psy);
 410}
 411
 412static int nvec_power_remove(struct platform_device *pdev)
 413{
 414        struct nvec_power *power = platform_get_drvdata(pdev);
 415
 416        cancel_delayed_work_sync(&power->poller);
 417        nvec_unregister_notifier(power->nvec, &power->notifier);
 418        switch (pdev->id) {
 419        case AC:
 420                power_supply_unregister(&nvec_psy);
 421                break;
 422        case BAT:
 423                power_supply_unregister(&nvec_bat_psy);
 424        }
 425
 426        return 0;
 427}
 428
 429static struct platform_driver nvec_power_driver = {
 430        .probe = nvec_power_probe,
 431        .remove = nvec_power_remove,
 432        .driver = {
 433                   .name = "nvec-power",
 434                   .owner = THIS_MODULE,
 435                   }
 436};
 437
 438module_platform_driver(nvec_power_driver);
 439
 440MODULE_AUTHOR("Ilya Petrov <ilya.muromec@gmail.com>");
 441MODULE_LICENSE("GPL");
 442MODULE_DESCRIPTION("NVEC battery and AC driver");