linux/arch/powerpc/xmon/ppc.h
<<
>>
Prefs
   1/* ppc.h -- Header file for PowerPC opcode table
   2   Copyright 1994, 1995, 1999, 2000, 2001, 2002, 2003, 2004, 2005, 2006
   3   Free Software Foundation, Inc.
   4   Written by Ian Lance Taylor, Cygnus Support
   5
   6This file is part of GDB, GAS, and the GNU binutils.
   7
   8GDB, GAS, and the GNU binutils are free software; you can redistribute
   9them and/or modify them under the terms of the GNU General Public
  10License as published by the Free Software Foundation; either version
  111, or (at your option) any later version.
  12
  13GDB, GAS, and the GNU binutils are distributed in the hope that they
  14will be useful, but WITHOUT ANY WARRANTY; without even the implied
  15warranty of MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE.  See
  16the GNU General Public License for more details.
  17
  18You should have received a copy of the GNU General Public License
  19along with this file; see the file COPYING.  If not, write to the Free
  20Software Foundation, 51 Franklin Street - Fifth Floor, Boston, MA 02110-1301, USA.  */
  21
  22#ifndef PPC_H
  23#define PPC_H
  24
  25/* The opcode table is an array of struct powerpc_opcode.  */
  26
  27struct powerpc_opcode
  28{
  29  /* The opcode name.  */
  30  const char *name;
  31
  32  /* The opcode itself.  Those bits which will be filled in with
  33     operands are zeroes.  */
  34  unsigned long opcode;
  35
  36  /* The opcode mask.  This is used by the disassembler.  This is a
  37     mask containing ones indicating those bits which must match the
  38     opcode field, and zeroes indicating those bits which need not
  39     match (and are presumably filled in by operands).  */
  40  unsigned long mask;
  41
  42  /* One bit flags for the opcode.  These are used to indicate which
  43     specific processors support the instructions.  The defined values
  44     are listed below.  */
  45  unsigned long flags;
  46
  47  /* An array of operand codes.  Each code is an index into the
  48     operand table.  They appear in the order which the operands must
  49     appear in assembly code, and are terminated by a zero.  */
  50  unsigned char operands[8];
  51};
  52
  53/* The table itself is sorted by major opcode number, and is otherwise
  54   in the order in which the disassembler should consider
  55   instructions.  */
  56extern const struct powerpc_opcode powerpc_opcodes[];
  57extern const int powerpc_num_opcodes;
  58
  59/* Values defined for the flags field of a struct powerpc_opcode.  */
  60
  61/* Opcode is defined for the PowerPC architecture.  */
  62#define PPC_OPCODE_PPC                   1
  63
  64/* Opcode is defined for the POWER (RS/6000) architecture.  */
  65#define PPC_OPCODE_POWER                 2
  66
  67/* Opcode is defined for the POWER2 (Rios 2) architecture.  */
  68#define PPC_OPCODE_POWER2                4
  69
  70/* Opcode is only defined on 32 bit architectures.  */
  71#define PPC_OPCODE_32                    8
  72
  73/* Opcode is only defined on 64 bit architectures.  */
  74#define PPC_OPCODE_64                 0x10
  75
  76/* Opcode is supported by the Motorola PowerPC 601 processor.  The 601
  77   is assumed to support all PowerPC (PPC_OPCODE_PPC) instructions,
  78   but it also supports many additional POWER instructions.  */
  79#define PPC_OPCODE_601                0x20
  80
  81/* Opcode is supported in both the Power and PowerPC architectures
  82   (ie, compiler's -mcpu=common or assembler's -mcom).  */
  83#define PPC_OPCODE_COMMON             0x40
  84
  85/* Opcode is supported for any Power or PowerPC platform (this is
  86   for the assembler's -many option, and it eliminates duplicates).  */
  87#define PPC_OPCODE_ANY                0x80
  88
  89/* Opcode is supported as part of the 64-bit bridge.  */
  90#define PPC_OPCODE_64_BRIDGE         0x100
  91
  92/* Opcode is supported by Altivec Vector Unit */
  93#define PPC_OPCODE_ALTIVEC           0x200
  94
  95/* Opcode is supported by PowerPC 403 processor.  */
  96#define PPC_OPCODE_403               0x400
  97
  98/* Opcode is supported by PowerPC BookE processor.  */
  99#define PPC_OPCODE_BOOKE             0x800
 100
 101/* Opcode is only supported by 64-bit PowerPC BookE processor.  */
 102#define PPC_OPCODE_BOOKE64          0x1000
 103
 104/* Opcode is supported by PowerPC 440 processor.  */
 105#define PPC_OPCODE_440              0x2000
 106
 107/* Opcode is only supported by Power4 architecture.  */
 108#define PPC_OPCODE_POWER4           0x4000
 109
 110/* Opcode isn't supported by Power4 architecture.  */
 111#define PPC_OPCODE_NOPOWER4         0x8000
 112
 113/* Opcode is only supported by POWERPC Classic architecture.  */
 114#define PPC_OPCODE_CLASSIC         0x10000
 115
 116/* Opcode is only supported by e500x2 Core.  */
 117#define PPC_OPCODE_SPE             0x20000
 118
 119/* Opcode is supported by e500x2 Integer select APU.  */
 120#define PPC_OPCODE_ISEL            0x40000
 121
 122/* Opcode is an e500 SPE floating point instruction.  */
 123#define PPC_OPCODE_EFS             0x80000
 124
 125/* Opcode is supported by branch locking APU.  */
 126#define PPC_OPCODE_BRLOCK         0x100000
 127
 128/* Opcode is supported by performance monitor APU.  */
 129#define PPC_OPCODE_PMR            0x200000
 130
 131/* Opcode is supported by cache locking APU.  */
 132#define PPC_OPCODE_CACHELCK       0x400000
 133
 134/* Opcode is supported by machine check APU.  */
 135#define PPC_OPCODE_RFMCI          0x800000
 136
 137/* Opcode is only supported by Power5 architecture.  */
 138#define PPC_OPCODE_POWER5        0x1000000
 139
 140/* Opcode is supported by PowerPC e300 family.  */
 141#define PPC_OPCODE_E300          0x2000000
 142
 143/* Opcode is only supported by Power6 architecture.  */
 144#define PPC_OPCODE_POWER6        0x4000000
 145
 146/* Opcode is only supported by PowerPC Cell family.  */
 147#define PPC_OPCODE_CELL          0x8000000
 148
 149/* A macro to extract the major opcode from an instruction.  */
 150#define PPC_OP(i) (((i) >> 26) & 0x3f)
 151
 152/* The operands table is an array of struct powerpc_operand.  */
 153
 154struct powerpc_operand
 155{
 156  /* The number of bits in the operand.  */
 157  int bits;
 158
 159  /* How far the operand is left shifted in the instruction.  */
 160  int shift;
 161
 162  /* Insertion function.  This is used by the assembler.  To insert an
 163     operand value into an instruction, check this field.
 164
 165     If it is NULL, execute
 166         i |= (op & ((1 << o->bits) - 1)) << o->shift;
 167     (i is the instruction which we are filling in, o is a pointer to
 168     this structure, and op is the opcode value; this assumes twos
 169     complement arithmetic).
 170
 171     If this field is not NULL, then simply call it with the
 172     instruction and the operand value.  It will return the new value
 173     of the instruction.  If the ERRMSG argument is not NULL, then if
 174     the operand value is illegal, *ERRMSG will be set to a warning
 175     string (the operand will be inserted in any case).  If the
 176     operand value is legal, *ERRMSG will be unchanged (most operands
 177     can accept any value).  */
 178  unsigned long (*insert)
 179    (unsigned long instruction, long op, int dialect, const char **errmsg);
 180
 181  /* Extraction function.  This is used by the disassembler.  To
 182     extract this operand type from an instruction, check this field.
 183
 184     If it is NULL, compute
 185         op = ((i) >> o->shift) & ((1 << o->bits) - 1);
 186         if ((o->flags & PPC_OPERAND_SIGNED) != 0
 187             && (op & (1 << (o->bits - 1))) != 0)
 188           op -= 1 << o->bits;
 189     (i is the instruction, o is a pointer to this structure, and op
 190     is the result; this assumes twos complement arithmetic).
 191
 192     If this field is not NULL, then simply call it with the
 193     instruction value.  It will return the value of the operand.  If
 194     the INVALID argument is not NULL, *INVALID will be set to
 195     non-zero if this operand type can not actually be extracted from
 196     this operand (i.e., the instruction does not match).  If the
 197     operand is valid, *INVALID will not be changed.  */
 198  long (*extract) (unsigned long instruction, int dialect, int *invalid);
 199
 200  /* One bit syntax flags.  */
 201  unsigned long flags;
 202};
 203
 204/* Elements in the table are retrieved by indexing with values from
 205   the operands field of the powerpc_opcodes table.  */
 206
 207extern const struct powerpc_operand powerpc_operands[];
 208
 209/* Values defined for the flags field of a struct powerpc_operand.  */
 210
 211/* This operand takes signed values.  */
 212#define PPC_OPERAND_SIGNED (01)
 213
 214/* This operand takes signed values, but also accepts a full positive
 215   range of values when running in 32 bit mode.  That is, if bits is
 216   16, it takes any value from -0x8000 to 0xffff.  In 64 bit mode,
 217   this flag is ignored.  */
 218#define PPC_OPERAND_SIGNOPT (02)
 219
 220/* This operand does not actually exist in the assembler input.  This
 221   is used to support extended mnemonics such as mr, for which two
 222   operands fields are identical.  The assembler should call the
 223   insert function with any op value.  The disassembler should call
 224   the extract function, ignore the return value, and check the value
 225   placed in the valid argument.  */
 226#define PPC_OPERAND_FAKE (04)
 227
 228/* The next operand should be wrapped in parentheses rather than
 229   separated from this one by a comma.  This is used for the load and
 230   store instructions which want their operands to look like
 231       reg,displacement(reg)
 232   */
 233#define PPC_OPERAND_PARENS (010)
 234
 235/* This operand may use the symbolic names for the CR fields, which
 236   are
 237       lt  0    gt  1   eq  2   so  3   un  3
 238       cr0 0    cr1 1   cr2 2   cr3 3
 239       cr4 4    cr5 5   cr6 6   cr7 7
 240   These may be combined arithmetically, as in cr2*4+gt.  These are
 241   only supported on the PowerPC, not the POWER.  */
 242#define PPC_OPERAND_CR (020)
 243
 244/* This operand names a register.  The disassembler uses this to print
 245   register names with a leading 'r'.  */
 246#define PPC_OPERAND_GPR (040)
 247
 248/* Like PPC_OPERAND_GPR, but don't print a leading 'r' for r0.  */
 249#define PPC_OPERAND_GPR_0 (0100)
 250
 251/* This operand names a floating point register.  The disassembler
 252   prints these with a leading 'f'.  */
 253#define PPC_OPERAND_FPR (0200)
 254
 255/* This operand is a relative branch displacement.  The disassembler
 256   prints these symbolically if possible.  */
 257#define PPC_OPERAND_RELATIVE (0400)
 258
 259/* This operand is an absolute branch address.  The disassembler
 260   prints these symbolically if possible.  */
 261#define PPC_OPERAND_ABSOLUTE (01000)
 262
 263/* This operand is optional, and is zero if omitted.  This is used for
 264   example, in the optional BF field in the comparison instructions.  The
 265   assembler must count the number of operands remaining on the line,
 266   and the number of operands remaining for the opcode, and decide
 267   whether this operand is present or not.  The disassembler should
 268   print this operand out only if it is not zero.  */
 269#define PPC_OPERAND_OPTIONAL (02000)
 270
 271/* This flag is only used with PPC_OPERAND_OPTIONAL.  If this operand
 272   is omitted, then for the next operand use this operand value plus
 273   1, ignoring the next operand field for the opcode.  This wretched
 274   hack is needed because the Power rotate instructions can take
 275   either 4 or 5 operands.  The disassembler should print this operand
 276   out regardless of the PPC_OPERAND_OPTIONAL field.  */
 277#define PPC_OPERAND_NEXT (04000)
 278
 279/* This operand should be regarded as a negative number for the
 280   purposes of overflow checking (i.e., the normal most negative
 281   number is disallowed and one more than the normal most positive
 282   number is allowed).  This flag will only be set for a signed
 283   operand.  */
 284#define PPC_OPERAND_NEGATIVE (010000)
 285
 286/* This operand names a vector unit register.  The disassembler
 287   prints these with a leading 'v'.  */
 288#define PPC_OPERAND_VR (020000)
 289
 290/* This operand is for the DS field in a DS form instruction.  */
 291#define PPC_OPERAND_DS (040000)
 292
 293/* This operand is for the DQ field in a DQ form instruction.  */
 294#define PPC_OPERAND_DQ (0100000)
 295
 296/* The POWER and PowerPC assemblers use a few macros.  We keep them
 297   with the operands table for simplicity.  The macro table is an
 298   array of struct powerpc_macro.  */
 299
 300struct powerpc_macro
 301{
 302  /* The macro name.  */
 303  const char *name;
 304
 305  /* The number of operands the macro takes.  */
 306  unsigned int operands;
 307
 308  /* One bit flags for the opcode.  These are used to indicate which
 309     specific processors support the instructions.  The values are the
 310     same as those for the struct powerpc_opcode flags field.  */
 311  unsigned long flags;
 312
 313  /* A format string to turn the macro into a normal instruction.
 314     Each %N in the string is replaced with operand number N (zero
 315     based).  */
 316  const char *format;
 317};
 318
 319extern const struct powerpc_macro powerpc_macros[];
 320extern const int powerpc_num_macros;
 321
 322#endif /* PPC_H */
 323