linux/drivers/power/supply/charger-manager.c
<<
>>
Prefs
   1/*
   2 * Copyright (C) 2011 Samsung Electronics Co., Ltd.
   3 * MyungJoo Ham <myungjoo.ham@samsung.com>
   4 *
   5 * This driver enables to monitor battery health and control charger
   6 * during suspend-to-mem.
   7 * Charger manager depends on other devices. register this later than
   8 * the depending devices.
   9 *
  10 * This program is free software; you can redistribute it and/or modify
  11 * it under the terms of the GNU General Public License version 2 as
  12 * published by the Free Software Foundation.
  13**/
  14
  15#define pr_fmt(fmt) KBUILD_MODNAME ": " fmt
  16
  17#include <linux/io.h>
  18#include <linux/module.h>
  19#include <linux/irq.h>
  20#include <linux/interrupt.h>
  21#include <linux/rtc.h>
  22#include <linux/slab.h>
  23#include <linux/workqueue.h>
  24#include <linux/platform_device.h>
  25#include <linux/power/charger-manager.h>
  26#include <linux/regulator/consumer.h>
  27#include <linux/sysfs.h>
  28#include <linux/of.h>
  29#include <linux/thermal.h>
  30
  31/*
  32 * Default termperature threshold for charging.
  33 * Every temperature units are in tenth of centigrade.
  34 */
  35#define CM_DEFAULT_RECHARGE_TEMP_DIFF   50
  36#define CM_DEFAULT_CHARGE_TEMP_MAX      500
  37
  38static const char * const default_event_names[] = {
  39        [CM_EVENT_UNKNOWN] = "Unknown",
  40        [CM_EVENT_BATT_FULL] = "Battery Full",
  41        [CM_EVENT_BATT_IN] = "Battery Inserted",
  42        [CM_EVENT_BATT_OUT] = "Battery Pulled Out",
  43        [CM_EVENT_BATT_OVERHEAT] = "Battery Overheat",
  44        [CM_EVENT_BATT_COLD] = "Battery Cold",
  45        [CM_EVENT_EXT_PWR_IN_OUT] = "External Power Attach/Detach",
  46        [CM_EVENT_CHG_START_STOP] = "Charging Start/Stop",
  47        [CM_EVENT_OTHERS] = "Other battery events"
  48};
  49
  50/*
  51 * Regard CM_JIFFIES_SMALL jiffies is small enough to ignore for
  52 * delayed works so that we can run delayed works with CM_JIFFIES_SMALL
  53 * without any delays.
  54 */
  55#define CM_JIFFIES_SMALL        (2)
  56
  57/* If y is valid (> 0) and smaller than x, do x = y */
  58#define CM_MIN_VALID(x, y)      x = (((y > 0) && ((x) > (y))) ? (y) : (x))
  59
  60/*
  61 * Regard CM_RTC_SMALL (sec) is small enough to ignore error in invoking
  62 * rtc alarm. It should be 2 or larger
  63 */
  64#define CM_RTC_SMALL            (2)
  65
  66#define UEVENT_BUF_SIZE         32
  67
  68static LIST_HEAD(cm_list);
  69static DEFINE_MUTEX(cm_list_mtx);
  70
  71/* About in-suspend (suspend-again) monitoring */
  72static struct alarm *cm_timer;
  73
  74static bool cm_suspended;
  75static bool cm_timer_set;
  76static unsigned long cm_suspend_duration_ms;
  77
  78/* About normal (not suspended) monitoring */
  79static unsigned long polling_jiffy = ULONG_MAX; /* ULONG_MAX: no polling */
  80static unsigned long next_polling; /* Next appointed polling time */
  81static struct workqueue_struct *cm_wq; /* init at driver add */
  82static struct delayed_work cm_monitor_work; /* init at driver add */
  83
  84/**
  85 * is_batt_present - See if the battery presents in place.
  86 * @cm: the Charger Manager representing the battery.
  87 */
  88static bool is_batt_present(struct charger_manager *cm)
  89{
  90        union power_supply_propval val;
  91        struct power_supply *psy;
  92        bool present = false;
  93        int i, ret;
  94
  95        switch (cm->desc->battery_present) {
  96        case CM_BATTERY_PRESENT:
  97                present = true;
  98                break;
  99        case CM_NO_BATTERY:
 100                break;
 101        case CM_FUEL_GAUGE:
 102                psy = power_supply_get_by_name(cm->desc->psy_fuel_gauge);
 103                if (!psy)
 104                        break;
 105
 106                ret = power_supply_get_property(psy, POWER_SUPPLY_PROP_PRESENT,
 107                                &val);
 108                if (ret == 0 && val.intval)
 109                        present = true;
 110                power_supply_put(psy);
 111                break;
 112        case CM_CHARGER_STAT:
 113                for (i = 0; cm->desc->psy_charger_stat[i]; i++) {
 114                        psy = power_supply_get_by_name(
 115                                        cm->desc->psy_charger_stat[i]);
 116                        if (!psy) {
 117                                dev_err(cm->dev, "Cannot find power supply \"%s\"\n",
 118                                        cm->desc->psy_charger_stat[i]);
 119                                continue;
 120                        }
 121
 122                        ret = power_supply_get_property(psy,
 123                                POWER_SUPPLY_PROP_PRESENT, &val);
 124                        power_supply_put(psy);
 125                        if (ret == 0 && val.intval) {
 126                                present = true;
 127                                break;
 128                        }
 129                }
 130                break;
 131        }
 132
 133        return present;
 134}
 135
 136/**
 137 * is_ext_pwr_online - See if an external power source is attached to charge
 138 * @cm: the Charger Manager representing the battery.
 139 *
 140 * Returns true if at least one of the chargers of the battery has an external
 141 * power source attached to charge the battery regardless of whether it is
 142 * actually charging or not.
 143 */
 144static bool is_ext_pwr_online(struct charger_manager *cm)
 145{
 146        union power_supply_propval val;
 147        struct power_supply *psy;
 148        bool online = false;
 149        int i, ret;
 150
 151        /* If at least one of them has one, it's yes. */
 152        for (i = 0; cm->desc->psy_charger_stat[i]; i++) {
 153                psy = power_supply_get_by_name(cm->desc->psy_charger_stat[i]);
 154                if (!psy) {
 155                        dev_err(cm->dev, "Cannot find power supply \"%s\"\n",
 156                                        cm->desc->psy_charger_stat[i]);
 157                        continue;
 158                }
 159
 160                ret = power_supply_get_property(psy, POWER_SUPPLY_PROP_ONLINE,
 161                                &val);
 162                power_supply_put(psy);
 163                if (ret == 0 && val.intval) {
 164                        online = true;
 165                        break;
 166                }
 167        }
 168
 169        return online;
 170}
 171
 172/**
 173 * get_batt_uV - Get the voltage level of the battery
 174 * @cm: the Charger Manager representing the battery.
 175 * @uV: the voltage level returned.
 176 *
 177 * Returns 0 if there is no error.
 178 * Returns a negative value on error.
 179 */
 180static int get_batt_uV(struct charger_manager *cm, int *uV)
 181{
 182        union power_supply_propval val;
 183        struct power_supply *fuel_gauge;
 184        int ret;
 185
 186        fuel_gauge = power_supply_get_by_name(cm->desc->psy_fuel_gauge);
 187        if (!fuel_gauge)
 188                return -ENODEV;
 189
 190        ret = power_supply_get_property(fuel_gauge,
 191                                POWER_SUPPLY_PROP_VOLTAGE_NOW, &val);
 192        power_supply_put(fuel_gauge);
 193        if (ret)
 194                return ret;
 195
 196        *uV = val.intval;
 197        return 0;
 198}
 199
 200/**
 201 * is_charging - Returns true if the battery is being charged.
 202 * @cm: the Charger Manager representing the battery.
 203 */
 204static bool is_charging(struct charger_manager *cm)
 205{
 206        int i, ret;
 207        bool charging = false;
 208        struct power_supply *psy;
 209        union power_supply_propval val;
 210
 211        /* If there is no battery, it cannot be charged */
 212        if (!is_batt_present(cm))
 213                return false;
 214
 215        /* If at least one of the charger is charging, return yes */
 216        for (i = 0; cm->desc->psy_charger_stat[i]; i++) {
 217                /* 1. The charger sholuld not be DISABLED */
 218                if (cm->emergency_stop)
 219                        continue;
 220                if (!cm->charger_enabled)
 221                        continue;
 222
 223                psy = power_supply_get_by_name(cm->desc->psy_charger_stat[i]);
 224                if (!psy) {
 225                        dev_err(cm->dev, "Cannot find power supply \"%s\"\n",
 226                                        cm->desc->psy_charger_stat[i]);
 227                        continue;
 228                }
 229
 230                /* 2. The charger should be online (ext-power) */
 231                ret = power_supply_get_property(psy, POWER_SUPPLY_PROP_ONLINE,
 232                                &val);
 233                if (ret) {
 234                        dev_warn(cm->dev, "Cannot read ONLINE value from %s\n",
 235                                 cm->desc->psy_charger_stat[i]);
 236                        power_supply_put(psy);
 237                        continue;
 238                }
 239                if (val.intval == 0) {
 240                        power_supply_put(psy);
 241                        continue;
 242                }
 243
 244                /*
 245                 * 3. The charger should not be FULL, DISCHARGING,
 246                 * or NOT_CHARGING.
 247                 */
 248                ret = power_supply_get_property(psy, POWER_SUPPLY_PROP_STATUS,
 249                                &val);
 250                power_supply_put(psy);
 251                if (ret) {
 252                        dev_warn(cm->dev, "Cannot read STATUS value from %s\n",
 253                                 cm->desc->psy_charger_stat[i]);
 254                        continue;
 255                }
 256                if (val.intval == POWER_SUPPLY_STATUS_FULL ||
 257                                val.intval == POWER_SUPPLY_STATUS_DISCHARGING ||
 258                                val.intval == POWER_SUPPLY_STATUS_NOT_CHARGING)
 259                        continue;
 260
 261                /* Then, this is charging. */
 262                charging = true;
 263                break;
 264        }
 265
 266        return charging;
 267}
 268
 269/**
 270 * is_full_charged - Returns true if the battery is fully charged.
 271 * @cm: the Charger Manager representing the battery.
 272 */
 273static bool is_full_charged(struct charger_manager *cm)
 274{
 275        struct charger_desc *desc = cm->desc;
 276        union power_supply_propval val;
 277        struct power_supply *fuel_gauge;
 278        bool is_full = false;
 279        int ret = 0;
 280        int uV;
 281
 282        /* If there is no battery, it cannot be charged */
 283        if (!is_batt_present(cm))
 284                return false;
 285
 286        fuel_gauge = power_supply_get_by_name(cm->desc->psy_fuel_gauge);
 287        if (!fuel_gauge)
 288                return false;
 289
 290        if (desc->fullbatt_full_capacity > 0) {
 291                val.intval = 0;
 292
 293                /* Not full if capacity of fuel gauge isn't full */
 294                ret = power_supply_get_property(fuel_gauge,
 295                                POWER_SUPPLY_PROP_CHARGE_FULL, &val);
 296                if (!ret && val.intval > desc->fullbatt_full_capacity) {
 297                        is_full = true;
 298                        goto out;
 299                }
 300        }
 301
 302        /* Full, if it's over the fullbatt voltage */
 303        if (desc->fullbatt_uV > 0) {
 304                ret = get_batt_uV(cm, &uV);
 305                if (!ret && uV >= desc->fullbatt_uV) {
 306                        is_full = true;
 307                        goto out;
 308                }
 309        }
 310
 311        /* Full, if the capacity is more than fullbatt_soc */
 312        if (desc->fullbatt_soc > 0) {
 313                val.intval = 0;
 314
 315                ret = power_supply_get_property(fuel_gauge,
 316                                POWER_SUPPLY_PROP_CAPACITY, &val);
 317                if (!ret && val.intval >= desc->fullbatt_soc) {
 318                        is_full = true;
 319                        goto out;
 320                }
 321        }
 322
 323out:
 324        power_supply_put(fuel_gauge);
 325        return is_full;
 326}
 327
 328/**
 329 * is_polling_required - Return true if need to continue polling for this CM.
 330 * @cm: the Charger Manager representing the battery.
 331 */
 332static bool is_polling_required(struct charger_manager *cm)
 333{
 334        switch (cm->desc->polling_mode) {
 335        case CM_POLL_DISABLE:
 336                return false;
 337        case CM_POLL_ALWAYS:
 338                return true;
 339        case CM_POLL_EXTERNAL_POWER_ONLY:
 340                return is_ext_pwr_online(cm);
 341        case CM_POLL_CHARGING_ONLY:
 342                return is_charging(cm);
 343        default:
 344                dev_warn(cm->dev, "Incorrect polling_mode (%d)\n",
 345                         cm->desc->polling_mode);
 346        }
 347
 348        return false;
 349}
 350
 351/**
 352 * try_charger_enable - Enable/Disable chargers altogether
 353 * @cm: the Charger Manager representing the battery.
 354 * @enable: true: enable / false: disable
 355 *
 356 * Note that Charger Manager keeps the charger enabled regardless whether
 357 * the charger is charging or not (because battery is full or no external
 358 * power source exists) except when CM needs to disable chargers forcibly
 359 * bacause of emergency causes; when the battery is overheated or too cold.
 360 */
 361static int try_charger_enable(struct charger_manager *cm, bool enable)
 362{
 363        int err = 0, i;
 364        struct charger_desc *desc = cm->desc;
 365
 366        /* Ignore if it's redundent command */
 367        if (enable == cm->charger_enabled)
 368                return 0;
 369
 370        if (enable) {
 371                if (cm->emergency_stop)
 372                        return -EAGAIN;
 373
 374                /*
 375                 * Save start time of charging to limit
 376                 * maximum possible charging time.
 377                 */
 378                cm->charging_start_time = ktime_to_ms(ktime_get());
 379                cm->charging_end_time = 0;
 380
 381                for (i = 0 ; i < desc->num_charger_regulators ; i++) {
 382                        if (desc->charger_regulators[i].externally_control)
 383                                continue;
 384
 385                        err = regulator_enable(desc->charger_regulators[i].consumer);
 386                        if (err < 0) {
 387                                dev_warn(cm->dev, "Cannot enable %s regulator\n",
 388                                         desc->charger_regulators[i].regulator_name);
 389                        }
 390                }
 391        } else {
 392                /*
 393                 * Save end time of charging to maintain fully charged state
 394                 * of battery after full-batt.
 395                 */
 396                cm->charging_start_time = 0;
 397                cm->charging_end_time = ktime_to_ms(ktime_get());
 398
 399                for (i = 0 ; i < desc->num_charger_regulators ; i++) {
 400                        if (desc->charger_regulators[i].externally_control)
 401                                continue;
 402
 403                        err = regulator_disable(desc->charger_regulators[i].consumer);
 404                        if (err < 0) {
 405                                dev_warn(cm->dev, "Cannot disable %s regulator\n",
 406                                         desc->charger_regulators[i].regulator_name);
 407                        }
 408                }
 409
 410                /*
 411                 * Abnormal battery state - Stop charging forcibly,
 412                 * even if charger was enabled at the other places
 413                 */
 414                for (i = 0; i < desc->num_charger_regulators; i++) {
 415                        if (regulator_is_enabled(
 416                                    desc->charger_regulators[i].consumer)) {
 417                                regulator_force_disable(
 418                                        desc->charger_regulators[i].consumer);
 419                                dev_warn(cm->dev, "Disable regulator(%s) forcibly\n",
 420                                         desc->charger_regulators[i].regulator_name);
 421                        }
 422                }
 423        }
 424
 425        if (!err)
 426                cm->charger_enabled = enable;
 427
 428        return err;
 429}
 430
 431/**
 432 * try_charger_restart - Restart charging.
 433 * @cm: the Charger Manager representing the battery.
 434 *
 435 * Restart charging by turning off and on the charger.
 436 */
 437static int try_charger_restart(struct charger_manager *cm)
 438{
 439        int err;
 440
 441        if (cm->emergency_stop)
 442                return -EAGAIN;
 443
 444        err = try_charger_enable(cm, false);
 445        if (err)
 446                return err;
 447
 448        return try_charger_enable(cm, true);
 449}
 450
 451/**
 452 * uevent_notify - Let users know something has changed.
 453 * @cm: the Charger Manager representing the battery.
 454 * @event: the event string.
 455 *
 456 * If @event is null, it implies that uevent_notify is called
 457 * by resume function. When called in the resume function, cm_suspended
 458 * should be already reset to false in order to let uevent_notify
 459 * notify the recent event during the suspend to users. While
 460 * suspended, uevent_notify does not notify users, but tracks
 461 * events so that uevent_notify can notify users later after resumed.
 462 */
 463static void uevent_notify(struct charger_manager *cm, const char *event)
 464{
 465        static char env_str[UEVENT_BUF_SIZE + 1] = "";
 466        static char env_str_save[UEVENT_BUF_SIZE + 1] = "";
 467
 468        if (cm_suspended) {
 469                /* Nothing in suspended-event buffer */
 470                if (env_str_save[0] == 0) {
 471                        if (!strncmp(env_str, event, UEVENT_BUF_SIZE))
 472                                return; /* status not changed */
 473                        strncpy(env_str_save, event, UEVENT_BUF_SIZE);
 474                        return;
 475                }
 476
 477                if (!strncmp(env_str_save, event, UEVENT_BUF_SIZE))
 478                        return; /* Duplicated. */
 479                strncpy(env_str_save, event, UEVENT_BUF_SIZE);
 480                return;
 481        }
 482
 483        if (event == NULL) {
 484                /* No messages pending */
 485                if (!env_str_save[0])
 486                        return;
 487
 488                strncpy(env_str, env_str_save, UEVENT_BUF_SIZE);
 489                kobject_uevent(&cm->dev->kobj, KOBJ_CHANGE);
 490                env_str_save[0] = 0;
 491
 492                return;
 493        }
 494
 495        /* status not changed */
 496        if (!strncmp(env_str, event, UEVENT_BUF_SIZE))
 497                return;
 498
 499        /* save the status and notify the update */
 500        strncpy(env_str, event, UEVENT_BUF_SIZE);
 501        kobject_uevent(&cm->dev->kobj, KOBJ_CHANGE);
 502
 503        dev_info(cm->dev, "%s\n", event);
 504}
 505
 506/**
 507 * fullbatt_vchk - Check voltage drop some times after "FULL" event.
 508 * @work: the work_struct appointing the function
 509 *
 510 * If a user has designated "fullbatt_vchkdrop_ms/uV" values with
 511 * charger_desc, Charger Manager checks voltage drop after the battery
 512 * "FULL" event. It checks whether the voltage has dropped more than
 513 * fullbatt_vchkdrop_uV by calling this function after fullbatt_vchkrop_ms.
 514 */
 515static void fullbatt_vchk(struct work_struct *work)
 516{
 517        struct delayed_work *dwork = to_delayed_work(work);
 518        struct charger_manager *cm = container_of(dwork,
 519                        struct charger_manager, fullbatt_vchk_work);
 520        struct charger_desc *desc = cm->desc;
 521        int batt_uV, err, diff;
 522
 523        /* remove the appointment for fullbatt_vchk */
 524        cm->fullbatt_vchk_jiffies_at = 0;
 525
 526        if (!desc->fullbatt_vchkdrop_uV || !desc->fullbatt_vchkdrop_ms)
 527                return;
 528
 529        err = get_batt_uV(cm, &batt_uV);
 530        if (err) {
 531                dev_err(cm->dev, "%s: get_batt_uV error(%d)\n", __func__, err);
 532                return;
 533        }
 534
 535        diff = desc->fullbatt_uV - batt_uV;
 536        if (diff < 0)
 537                return;
 538
 539        dev_info(cm->dev, "VBATT dropped %duV after full-batt\n", diff);
 540
 541        if (diff > desc->fullbatt_vchkdrop_uV) {
 542                try_charger_restart(cm);
 543                uevent_notify(cm, "Recharging");
 544        }
 545}
 546
 547/**
 548 * check_charging_duration - Monitor charging/discharging duration
 549 * @cm: the Charger Manager representing the battery.
 550 *
 551 * If whole charging duration exceed 'charging_max_duration_ms',
 552 * cm stop charging to prevent overcharge/overheat. If discharging
 553 * duration exceed 'discharging _max_duration_ms', charger cable is
 554 * attached, after full-batt, cm start charging to maintain fully
 555 * charged state for battery.
 556 */
 557static int check_charging_duration(struct charger_manager *cm)
 558{
 559        struct charger_desc *desc = cm->desc;
 560        u64 curr = ktime_to_ms(ktime_get());
 561        u64 duration;
 562        int ret = false;
 563
 564        if (!desc->charging_max_duration_ms &&
 565                        !desc->discharging_max_duration_ms)
 566                return ret;
 567
 568        if (cm->charger_enabled) {
 569                duration = curr - cm->charging_start_time;
 570
 571                if (duration > desc->charging_max_duration_ms) {
 572                        dev_info(cm->dev, "Charging duration exceed %ums\n",
 573                                 desc->charging_max_duration_ms);
 574                        uevent_notify(cm, "Discharging");
 575                        try_charger_enable(cm, false);
 576                        ret = true;
 577                }
 578        } else if (is_ext_pwr_online(cm) && !cm->charger_enabled) {
 579                duration = curr - cm->charging_end_time;
 580
 581                if (duration > desc->discharging_max_duration_ms &&
 582                                is_ext_pwr_online(cm)) {
 583                        dev_info(cm->dev, "Discharging duration exceed %ums\n",
 584                                 desc->discharging_max_duration_ms);
 585                        uevent_notify(cm, "Recharging");
 586                        try_charger_enable(cm, true);
 587                        ret = true;
 588                }
 589        }
 590
 591        return ret;
 592}
 593
 594static int cm_get_battery_temperature_by_psy(struct charger_manager *cm,
 595                                        int *temp)
 596{
 597        struct power_supply *fuel_gauge;
 598        int ret;
 599
 600        fuel_gauge = power_supply_get_by_name(cm->desc->psy_fuel_gauge);
 601        if (!fuel_gauge)
 602                return -ENODEV;
 603
 604        ret = power_supply_get_property(fuel_gauge,
 605                                POWER_SUPPLY_PROP_TEMP,
 606                                (union power_supply_propval *)temp);
 607        power_supply_put(fuel_gauge);
 608
 609        return ret;
 610}
 611
 612static int cm_get_battery_temperature(struct charger_manager *cm,
 613                                        int *temp)
 614{
 615        int ret;
 616
 617        if (!cm->desc->measure_battery_temp)
 618                return -ENODEV;
 619
 620#ifdef CONFIG_THERMAL
 621        if (cm->tzd_batt) {
 622                ret = thermal_zone_get_temp(cm->tzd_batt, temp);
 623                if (!ret)
 624                        /* Calibrate temperature unit */
 625                        *temp /= 100;
 626        } else
 627#endif
 628        {
 629                /* if-else continued from CONFIG_THERMAL */
 630                ret = cm_get_battery_temperature_by_psy(cm, temp);
 631        }
 632
 633        return ret;
 634}
 635
 636static int cm_check_thermal_status(struct charger_manager *cm)
 637{
 638        struct charger_desc *desc = cm->desc;
 639        int temp, upper_limit, lower_limit;
 640        int ret = 0;
 641
 642        ret = cm_get_battery_temperature(cm, &temp);
 643        if (ret) {
 644                /* FIXME:
 645                 * No information of battery temperature might
 646                 * occur hazadous result. We have to handle it
 647                 * depending on battery type.
 648                 */
 649                dev_err(cm->dev, "Failed to get battery temperature\n");
 650                return 0;
 651        }
 652
 653        upper_limit = desc->temp_max;
 654        lower_limit = desc->temp_min;
 655
 656        if (cm->emergency_stop) {
 657                upper_limit -= desc->temp_diff;
 658                lower_limit += desc->temp_diff;
 659        }
 660
 661        if (temp > upper_limit)
 662                ret = CM_EVENT_BATT_OVERHEAT;
 663        else if (temp < lower_limit)
 664                ret = CM_EVENT_BATT_COLD;
 665
 666        return ret;
 667}
 668
 669/**
 670 * _cm_monitor - Monitor the temperature and return true for exceptions.
 671 * @cm: the Charger Manager representing the battery.
 672 *
 673 * Returns true if there is an event to notify for the battery.
 674 * (True if the status of "emergency_stop" changes)
 675 */
 676static bool _cm_monitor(struct charger_manager *cm)
 677{
 678        int temp_alrt;
 679
 680        temp_alrt = cm_check_thermal_status(cm);
 681
 682        /* It has been stopped already */
 683        if (temp_alrt && cm->emergency_stop)
 684                return false;
 685
 686        /*
 687         * Check temperature whether overheat or cold.
 688         * If temperature is out of range normal state, stop charging.
 689         */
 690        if (temp_alrt) {
 691                cm->emergency_stop = temp_alrt;
 692                if (!try_charger_enable(cm, false))
 693                        uevent_notify(cm, default_event_names[temp_alrt]);
 694
 695        /*
 696         * Check whole charging duration and discharing duration
 697         * after full-batt.
 698         */
 699        } else if (!cm->emergency_stop && check_charging_duration(cm)) {
 700                dev_dbg(cm->dev,
 701                        "Charging/Discharging duration is out of range\n");
 702        /*
 703         * Check dropped voltage of battery. If battery voltage is more
 704         * dropped than fullbatt_vchkdrop_uV after fully charged state,
 705         * charger-manager have to recharge battery.
 706         */
 707        } else if (!cm->emergency_stop && is_ext_pwr_online(cm) &&
 708                        !cm->charger_enabled) {
 709                fullbatt_vchk(&cm->fullbatt_vchk_work.work);
 710
 711        /*
 712         * Check whether fully charged state to protect overcharge
 713         * if charger-manager is charging for battery.
 714         */
 715        } else if (!cm->emergency_stop && is_full_charged(cm) &&
 716                        cm->charger_enabled) {
 717                dev_info(cm->dev, "EVENT_HANDLE: Battery Fully Charged\n");
 718                uevent_notify(cm, default_event_names[CM_EVENT_BATT_FULL]);
 719
 720                try_charger_enable(cm, false);
 721
 722                fullbatt_vchk(&cm->fullbatt_vchk_work.work);
 723        } else {
 724                cm->emergency_stop = 0;
 725                if (is_ext_pwr_online(cm)) {
 726                        if (!try_charger_enable(cm, true))
 727                                uevent_notify(cm, "CHARGING");
 728                }
 729        }
 730
 731        return true;
 732}
 733
 734/**
 735 * cm_monitor - Monitor every battery.
 736 *
 737 * Returns true if there is an event to notify from any of the batteries.
 738 * (True if the status of "emergency_stop" changes)
 739 */
 740static bool cm_monitor(void)
 741{
 742        bool stop = false;
 743        struct charger_manager *cm;
 744
 745        mutex_lock(&cm_list_mtx);
 746
 747        list_for_each_entry(cm, &cm_list, entry) {
 748                if (_cm_monitor(cm))
 749                        stop = true;
 750        }
 751
 752        mutex_unlock(&cm_list_mtx);
 753
 754        return stop;
 755}
 756
 757/**
 758 * _setup_polling - Setup the next instance of polling.
 759 * @work: work_struct of the function _setup_polling.
 760 */
 761static void _setup_polling(struct work_struct *work)
 762{
 763        unsigned long min = ULONG_MAX;
 764        struct charger_manager *cm;
 765        bool keep_polling = false;
 766        unsigned long _next_polling;
 767
 768        mutex_lock(&cm_list_mtx);
 769
 770        list_for_each_entry(cm, &cm_list, entry) {
 771                if (is_polling_required(cm) && cm->desc->polling_interval_ms) {
 772                        keep_polling = true;
 773
 774                        if (min > cm->desc->polling_interval_ms)
 775                                min = cm->desc->polling_interval_ms;
 776                }
 777        }
 778
 779        polling_jiffy = msecs_to_jiffies(min);
 780        if (polling_jiffy <= CM_JIFFIES_SMALL)
 781                polling_jiffy = CM_JIFFIES_SMALL + 1;
 782
 783        if (!keep_polling)
 784                polling_jiffy = ULONG_MAX;
 785        if (polling_jiffy == ULONG_MAX)
 786                goto out;
 787
 788        WARN(cm_wq == NULL, "charger-manager: workqueue not initialized"
 789                            ". try it later. %s\n", __func__);
 790
 791        /*
 792         * Use mod_delayed_work() iff the next polling interval should
 793         * occur before the currently scheduled one.  If @cm_monitor_work
 794         * isn't active, the end result is the same, so no need to worry
 795         * about stale @next_polling.
 796         */
 797        _next_polling = jiffies + polling_jiffy;
 798
 799        if (time_before(_next_polling, next_polling)) {
 800                mod_delayed_work(cm_wq, &cm_monitor_work, polling_jiffy);
 801                next_polling = _next_polling;
 802        } else {
 803                if (queue_delayed_work(cm_wq, &cm_monitor_work, polling_jiffy))
 804                        next_polling = _next_polling;
 805        }
 806out:
 807        mutex_unlock(&cm_list_mtx);
 808}
 809static DECLARE_WORK(setup_polling, _setup_polling);
 810
 811/**
 812 * cm_monitor_poller - The Monitor / Poller.
 813 * @work: work_struct of the function cm_monitor_poller
 814 *
 815 * During non-suspended state, cm_monitor_poller is used to poll and monitor
 816 * the batteries.
 817 */
 818static void cm_monitor_poller(struct work_struct *work)
 819{
 820        cm_monitor();
 821        schedule_work(&setup_polling);
 822}
 823
 824/**
 825 * fullbatt_handler - Event handler for CM_EVENT_BATT_FULL
 826 * @cm: the Charger Manager representing the battery.
 827 */
 828static void fullbatt_handler(struct charger_manager *cm)
 829{
 830        struct charger_desc *desc = cm->desc;
 831
 832        if (!desc->fullbatt_vchkdrop_uV || !desc->fullbatt_vchkdrop_ms)
 833                goto out;
 834
 835        if (cm_suspended)
 836                device_set_wakeup_capable(cm->dev, true);
 837
 838        mod_delayed_work(cm_wq, &cm->fullbatt_vchk_work,
 839                         msecs_to_jiffies(desc->fullbatt_vchkdrop_ms));
 840        cm->fullbatt_vchk_jiffies_at = jiffies + msecs_to_jiffies(
 841                                       desc->fullbatt_vchkdrop_ms);
 842
 843        if (cm->fullbatt_vchk_jiffies_at == 0)
 844                cm->fullbatt_vchk_jiffies_at = 1;
 845
 846out:
 847        dev_info(cm->dev, "EVENT_HANDLE: Battery Fully Charged\n");
 848        uevent_notify(cm, default_event_names[CM_EVENT_BATT_FULL]);
 849}
 850
 851/**
 852 * battout_handler - Event handler for CM_EVENT_BATT_OUT
 853 * @cm: the Charger Manager representing the battery.
 854 */
 855static void battout_handler(struct charger_manager *cm)
 856{
 857        if (cm_suspended)
 858                device_set_wakeup_capable(cm->dev, true);
 859
 860        if (!is_batt_present(cm)) {
 861                dev_emerg(cm->dev, "Battery Pulled Out!\n");
 862                uevent_notify(cm, default_event_names[CM_EVENT_BATT_OUT]);
 863        } else {
 864                uevent_notify(cm, "Battery Reinserted?");
 865        }
 866}
 867
 868/**
 869 * misc_event_handler - Handler for other evnets
 870 * @cm: the Charger Manager representing the battery.
 871 * @type: the Charger Manager representing the battery.
 872 */
 873static void misc_event_handler(struct charger_manager *cm,
 874                        enum cm_event_types type)
 875{
 876        if (cm_suspended)
 877                device_set_wakeup_capable(cm->dev, true);
 878
 879        if (is_polling_required(cm) && cm->desc->polling_interval_ms)
 880                schedule_work(&setup_polling);
 881        uevent_notify(cm, default_event_names[type]);
 882}
 883
 884static int charger_get_property(struct power_supply *psy,
 885                enum power_supply_property psp,
 886                union power_supply_propval *val)
 887{
 888        struct charger_manager *cm = power_supply_get_drvdata(psy);
 889        struct charger_desc *desc = cm->desc;
 890        struct power_supply *fuel_gauge = NULL;
 891        int ret = 0;
 892        int uV;
 893
 894        switch (psp) {
 895        case POWER_SUPPLY_PROP_STATUS:
 896                if (is_charging(cm))
 897                        val->intval = POWER_SUPPLY_STATUS_CHARGING;
 898                else if (is_ext_pwr_online(cm))
 899                        val->intval = POWER_SUPPLY_STATUS_NOT_CHARGING;
 900                else
 901                        val->intval = POWER_SUPPLY_STATUS_DISCHARGING;
 902                break;
 903        case POWER_SUPPLY_PROP_HEALTH:
 904                if (cm->emergency_stop > 0)
 905                        val->intval = POWER_SUPPLY_HEALTH_OVERHEAT;
 906                else if (cm->emergency_stop < 0)
 907                        val->intval = POWER_SUPPLY_HEALTH_COLD;
 908                else
 909                        val->intval = POWER_SUPPLY_HEALTH_GOOD;
 910                break;
 911        case POWER_SUPPLY_PROP_PRESENT:
 912                if (is_batt_present(cm))
 913                        val->intval = 1;
 914                else
 915                        val->intval = 0;
 916                break;
 917        case POWER_SUPPLY_PROP_VOLTAGE_NOW:
 918                ret = get_batt_uV(cm, &val->intval);
 919                break;
 920        case POWER_SUPPLY_PROP_CURRENT_NOW:
 921                fuel_gauge = power_supply_get_by_name(cm->desc->psy_fuel_gauge);
 922                if (!fuel_gauge) {
 923                        ret = -ENODEV;
 924                        break;
 925                }
 926                ret = power_supply_get_property(fuel_gauge,
 927                                POWER_SUPPLY_PROP_CURRENT_NOW, val);
 928                break;
 929        case POWER_SUPPLY_PROP_TEMP:
 930        case POWER_SUPPLY_PROP_TEMP_AMBIENT:
 931                return cm_get_battery_temperature(cm, &val->intval);
 932        case POWER_SUPPLY_PROP_CAPACITY:
 933                if (!is_batt_present(cm)) {
 934                        /* There is no battery. Assume 100% */
 935                        val->intval = 100;
 936                        break;
 937                }
 938
 939                fuel_gauge = power_supply_get_by_name(cm->desc->psy_fuel_gauge);
 940                if (!fuel_gauge) {
 941                        ret = -ENODEV;
 942                        break;
 943                }
 944
 945                ret = power_supply_get_property(fuel_gauge,
 946                                        POWER_SUPPLY_PROP_CAPACITY, val);
 947                if (ret)
 948                        break;
 949
 950                if (val->intval > 100) {
 951                        val->intval = 100;
 952                        break;
 953                }
 954                if (val->intval < 0)
 955                        val->intval = 0;
 956
 957                /* Do not adjust SOC when charging: voltage is overrated */
 958                if (is_charging(cm))
 959                        break;
 960
 961                /*
 962                 * If the capacity value is inconsistent, calibrate it base on
 963                 * the battery voltage values and the thresholds given as desc
 964                 */
 965                ret = get_batt_uV(cm, &uV);
 966                if (ret) {
 967                        /* Voltage information not available. No calibration */
 968                        ret = 0;
 969                        break;
 970                }
 971
 972                if (desc->fullbatt_uV > 0 && uV >= desc->fullbatt_uV &&
 973                    !is_charging(cm)) {
 974                        val->intval = 100;
 975                        break;
 976                }
 977
 978                break;
 979        case POWER_SUPPLY_PROP_ONLINE:
 980                if (is_ext_pwr_online(cm))
 981                        val->intval = 1;
 982                else
 983                        val->intval = 0;
 984                break;
 985        case POWER_SUPPLY_PROP_CHARGE_FULL:
 986                if (is_full_charged(cm))
 987                        val->intval = 1;
 988                else
 989                        val->intval = 0;
 990                ret = 0;
 991                break;
 992        case POWER_SUPPLY_PROP_CHARGE_NOW:
 993                if (is_charging(cm)) {
 994                        fuel_gauge = power_supply_get_by_name(
 995                                        cm->desc->psy_fuel_gauge);
 996                        if (!fuel_gauge) {
 997                                ret = -ENODEV;
 998                                break;
 999                        }
1000
1001                        ret = power_supply_get_property(fuel_gauge,
1002                                                POWER_SUPPLY_PROP_CHARGE_NOW,
1003                                                val);
1004                        if (ret) {
1005                                val->intval = 1;
1006                                ret = 0;
1007                        } else {
1008                                /* If CHARGE_NOW is supplied, use it */
1009                                val->intval = (val->intval > 0) ?
1010                                                val->intval : 1;
1011                        }
1012                } else {
1013                        val->intval = 0;
1014                }
1015                break;
1016        default:
1017                return -EINVAL;
1018        }
1019        if (fuel_gauge)
1020                power_supply_put(fuel_gauge);
1021        return ret;
1022}
1023
1024#define NUM_CHARGER_PSY_OPTIONAL        (4)
1025static enum power_supply_property default_charger_props[] = {
1026        /* Guaranteed to provide */
1027        POWER_SUPPLY_PROP_STATUS,
1028        POWER_SUPPLY_PROP_HEALTH,
1029        POWER_SUPPLY_PROP_PRESENT,
1030        POWER_SUPPLY_PROP_VOLTAGE_NOW,
1031        POWER_SUPPLY_PROP_CAPACITY,
1032        POWER_SUPPLY_PROP_ONLINE,
1033        POWER_SUPPLY_PROP_CHARGE_FULL,
1034        /*
1035         * Optional properties are:
1036         * POWER_SUPPLY_PROP_CHARGE_NOW,
1037         * POWER_SUPPLY_PROP_CURRENT_NOW,
1038         * POWER_SUPPLY_PROP_TEMP, and
1039         * POWER_SUPPLY_PROP_TEMP_AMBIENT,
1040         */
1041};
1042
1043static const struct power_supply_desc psy_default = {
1044        .name = "battery",
1045        .type = POWER_SUPPLY_TYPE_BATTERY,
1046        .properties = default_charger_props,
1047        .num_properties = ARRAY_SIZE(default_charger_props),
1048        .get_property = charger_get_property,
1049        .no_thermal = true,
1050};
1051
1052/**
1053 * cm_setup_timer - For in-suspend monitoring setup wakeup alarm
1054 *                  for suspend_again.
1055 *
1056 * Returns true if the alarm is set for Charger Manager to use.
1057 * Returns false if
1058 *      cm_setup_timer fails to set an alarm,
1059 *      cm_setup_timer does not need to set an alarm for Charger Manager,
1060 *      or an alarm previously configured is to be used.
1061 */
1062static bool cm_setup_timer(void)
1063{
1064        struct charger_manager *cm;
1065        unsigned int wakeup_ms = UINT_MAX;
1066        int timer_req = 0;
1067
1068        if (time_after(next_polling, jiffies))
1069                CM_MIN_VALID(wakeup_ms,
1070                        jiffies_to_msecs(next_polling - jiffies));
1071
1072        mutex_lock(&cm_list_mtx);
1073        list_for_each_entry(cm, &cm_list, entry) {
1074                unsigned int fbchk_ms = 0;
1075
1076                /* fullbatt_vchk is required. setup timer for that */
1077                if (cm->fullbatt_vchk_jiffies_at) {
1078                        fbchk_ms = jiffies_to_msecs(cm->fullbatt_vchk_jiffies_at
1079                                                    - jiffies);
1080                        if (time_is_before_eq_jiffies(
1081                                cm->fullbatt_vchk_jiffies_at) ||
1082                                msecs_to_jiffies(fbchk_ms) < CM_JIFFIES_SMALL) {
1083                                fullbatt_vchk(&cm->fullbatt_vchk_work.work);
1084                                fbchk_ms = 0;
1085                        }
1086                }
1087                CM_MIN_VALID(wakeup_ms, fbchk_ms);
1088
1089                /* Skip if polling is not required for this CM */
1090                if (!is_polling_required(cm) && !cm->emergency_stop)
1091                        continue;
1092                timer_req++;
1093                if (cm->desc->polling_interval_ms == 0)
1094                        continue;
1095                CM_MIN_VALID(wakeup_ms, cm->desc->polling_interval_ms);
1096        }
1097        mutex_unlock(&cm_list_mtx);
1098
1099        if (timer_req && cm_timer) {
1100                ktime_t now, add;
1101
1102                /*
1103                 * Set alarm with the polling interval (wakeup_ms)
1104                 * The alarm time should be NOW + CM_RTC_SMALL or later.
1105                 */
1106                if (wakeup_ms == UINT_MAX ||
1107                        wakeup_ms < CM_RTC_SMALL * MSEC_PER_SEC)
1108                        wakeup_ms = 2 * CM_RTC_SMALL * MSEC_PER_SEC;
1109
1110                pr_info("Charger Manager wakeup timer: %u ms\n", wakeup_ms);
1111
1112                now = ktime_get_boottime();
1113                add = ktime_set(wakeup_ms / MSEC_PER_SEC,
1114                                (wakeup_ms % MSEC_PER_SEC) * NSEC_PER_MSEC);
1115                alarm_start(cm_timer, ktime_add(now, add));
1116
1117                cm_suspend_duration_ms = wakeup_ms;
1118
1119                return true;
1120        }
1121        return false;
1122}
1123
1124/**
1125 * charger_extcon_work - enable/diable charger according to the state
1126 *                      of charger cable
1127 *
1128 * @work: work_struct of the function charger_extcon_work.
1129 */
1130static void charger_extcon_work(struct work_struct *work)
1131{
1132        struct charger_cable *cable =
1133                        container_of(work, struct charger_cable, wq);
1134        int ret;
1135
1136        if (cable->attached && cable->min_uA != 0 && cable->max_uA != 0) {
1137                ret = regulator_set_current_limit(cable->charger->consumer,
1138                                        cable->min_uA, cable->max_uA);
1139                if (ret < 0) {
1140                        pr_err("Cannot set current limit of %s (%s)\n",
1141                               cable->charger->regulator_name, cable->name);
1142                        return;
1143                }
1144
1145                pr_info("Set current limit of %s : %duA ~ %duA\n",
1146                        cable->charger->regulator_name,
1147                        cable->min_uA, cable->max_uA);
1148        }
1149
1150        try_charger_enable(cable->cm, cable->attached);
1151}
1152
1153/**
1154 * charger_extcon_notifier - receive the state of charger cable
1155 *                      when registered cable is attached or detached.
1156 *
1157 * @self: the notifier block of the charger_extcon_notifier.
1158 * @event: the cable state.
1159 * @ptr: the data pointer of notifier block.
1160 */
1161static int charger_extcon_notifier(struct notifier_block *self,
1162                        unsigned long event, void *ptr)
1163{
1164        struct charger_cable *cable =
1165                container_of(self, struct charger_cable, nb);
1166
1167        /*
1168         * The newly state of charger cable.
1169         * If cable is attached, cable->attached is true.
1170         */
1171        cable->attached = event;
1172
1173        /*
1174         * Setup monitoring to check battery state
1175         * when charger cable is attached.
1176         */
1177        if (cable->attached && is_polling_required(cable->cm)) {
1178                cancel_work_sync(&setup_polling);
1179                schedule_work(&setup_polling);
1180        }
1181
1182        /*
1183         * Setup work for controlling charger(regulator)
1184         * according to charger cable.
1185         */
1186        schedule_work(&cable->wq);
1187
1188        return NOTIFY_DONE;
1189}
1190
1191/**
1192 * charger_extcon_init - register external connector to use it
1193 *                      as the charger cable
1194 *
1195 * @cm: the Charger Manager representing the battery.
1196 * @cable: the Charger cable representing the external connector.
1197 */
1198static int charger_extcon_init(struct charger_manager *cm,
1199                struct charger_cable *cable)
1200{
1201        int ret;
1202
1203        /*
1204         * Charger manager use Extcon framework to identify
1205         * the charger cable among various external connector
1206         * cable (e.g., TA, USB, MHL, Dock).
1207         */
1208        INIT_WORK(&cable->wq, charger_extcon_work);
1209        cable->nb.notifier_call = charger_extcon_notifier;
1210        ret = extcon_register_interest(&cable->extcon_dev,
1211                        cable->extcon_name, cable->name, &cable->nb);
1212        if (ret < 0) {
1213                pr_info("Cannot register extcon_dev for %s(cable: %s)\n",
1214                        cable->extcon_name, cable->name);
1215                ret = -EINVAL;
1216        }
1217
1218        return ret;
1219}
1220
1221/**
1222 * charger_manager_register_extcon - Register extcon device to recevie state
1223 *                                   of charger cable.
1224 * @cm: the Charger Manager representing the battery.
1225 *
1226 * This function support EXTCON(External Connector) subsystem to detect the
1227 * state of charger cables for enabling or disabling charger(regulator) and
1228 * select the charger cable for charging among a number of external cable
1229 * according to policy of H/W board.
1230 */
1231static int charger_manager_register_extcon(struct charger_manager *cm)
1232{
1233        struct charger_desc *desc = cm->desc;
1234        struct charger_regulator *charger;
1235        int ret;
1236        int i;
1237        int j;
1238
1239        for (i = 0; i < desc->num_charger_regulators; i++) {
1240                charger = &desc->charger_regulators[i];
1241
1242                charger->consumer = regulator_get(cm->dev,
1243                                        charger->regulator_name);
1244                if (IS_ERR(charger->consumer)) {
1245                        dev_err(cm->dev, "Cannot find charger(%s)\n",
1246                                charger->regulator_name);
1247                        return PTR_ERR(charger->consumer);
1248                }
1249                charger->cm = cm;
1250
1251                for (j = 0; j < charger->num_cables; j++) {
1252                        struct charger_cable *cable = &charger->cables[j];
1253
1254                        ret = charger_extcon_init(cm, cable);
1255                        if (ret < 0) {
1256                                dev_err(cm->dev, "Cannot initialize charger(%s)\n",
1257                                        charger->regulator_name);
1258                                return ret;
1259                        }
1260                        cable->charger = charger;
1261                        cable->cm = cm;
1262                }
1263        }
1264
1265        return 0;
1266}
1267
1268/* help function of sysfs node to control charger(regulator) */
1269static ssize_t charger_name_show(struct device *dev,
1270                                struct device_attribute *attr, char *buf)
1271{
1272        struct charger_regulator *charger
1273                = container_of(attr, struct charger_regulator, attr_name);
1274
1275        return sprintf(buf, "%s\n", charger->regulator_name);
1276}
1277
1278static ssize_t charger_state_show(struct device *dev,
1279                                struct device_attribute *attr, char *buf)
1280{
1281        struct charger_regulator *charger
1282                = container_of(attr, struct charger_regulator, attr_state);
1283        int state = 0;
1284
1285        if (!charger->externally_control)
1286                state = regulator_is_enabled(charger->consumer);
1287
1288        return sprintf(buf, "%s\n", state ? "enabled" : "disabled");
1289}
1290
1291static ssize_t charger_externally_control_show(struct device *dev,
1292                                struct device_attribute *attr, char *buf)
1293{
1294        struct charger_regulator *charger = container_of(attr,
1295                        struct charger_regulator, attr_externally_control);
1296
1297        return sprintf(buf, "%d\n", charger->externally_control);
1298}
1299
1300static ssize_t charger_externally_control_store(struct device *dev,
1301                                struct device_attribute *attr, const char *buf,
1302                                size_t count)
1303{
1304        struct charger_regulator *charger
1305                = container_of(attr, struct charger_regulator,
1306                                        attr_externally_control);
1307        struct charger_manager *cm = charger->cm;
1308        struct charger_desc *desc = cm->desc;
1309        int i;
1310        int ret;
1311        int externally_control;
1312        int chargers_externally_control = 1;
1313
1314        ret = sscanf(buf, "%d", &externally_control);
1315        if (ret == 0) {
1316                ret = -EINVAL;
1317                return ret;
1318        }
1319
1320        if (!externally_control) {
1321                charger->externally_control = 0;
1322                return count;
1323        }
1324
1325        for (i = 0; i < desc->num_charger_regulators; i++) {
1326                if (&desc->charger_regulators[i] != charger &&
1327                        !desc->charger_regulators[i].externally_control) {
1328                        /*
1329                         * At least, one charger is controlled by
1330                         * charger-manager
1331                         */
1332                        chargers_externally_control = 0;
1333                        break;
1334                }
1335        }
1336
1337        if (!chargers_externally_control) {
1338                if (cm->charger_enabled) {
1339                        try_charger_enable(charger->cm, false);
1340                        charger->externally_control = externally_control;
1341                        try_charger_enable(charger->cm, true);
1342                } else {
1343                        charger->externally_control = externally_control;
1344                }
1345        } else {
1346                dev_warn(cm->dev,
1347                         "'%s' regulator should be controlled in charger-manager because charger-manager must need at least one charger for charging\n",
1348                         charger->regulator_name);
1349        }
1350
1351        return count;
1352}
1353
1354/**
1355 * charger_manager_register_sysfs - Register sysfs entry for each charger
1356 * @cm: the Charger Manager representing the battery.
1357 *
1358 * This function add sysfs entry for charger(regulator) to control charger from
1359 * user-space. If some development board use one more chargers for charging
1360 * but only need one charger on specific case which is dependent on user
1361 * scenario or hardware restrictions, the user enter 1 or 0(zero) to '/sys/
1362 * class/power_supply/battery/charger.[index]/externally_control'. For example,
1363 * if user enter 1 to 'sys/class/power_supply/battery/charger.[index]/
1364 * externally_control, this charger isn't controlled from charger-manager and
1365 * always stay off state of regulator.
1366 */
1367static int charger_manager_register_sysfs(struct charger_manager *cm)
1368{
1369        struct charger_desc *desc = cm->desc;
1370        struct charger_regulator *charger;
1371        int chargers_externally_control = 1;
1372        char buf[11];
1373        char *str;
1374        int ret;
1375        int i;
1376
1377        /* Create sysfs entry to control charger(regulator) */
1378        for (i = 0; i < desc->num_charger_regulators; i++) {
1379                charger = &desc->charger_regulators[i];
1380
1381                snprintf(buf, 10, "charger.%d", i);
1382                str = devm_kzalloc(cm->dev,
1383                                sizeof(char) * (strlen(buf) + 1), GFP_KERNEL);
1384                if (!str)
1385                        return -ENOMEM;
1386
1387                strcpy(str, buf);
1388
1389                charger->attrs[0] = &charger->attr_name.attr;
1390                charger->attrs[1] = &charger->attr_state.attr;
1391                charger->attrs[2] = &charger->attr_externally_control.attr;
1392                charger->attrs[3] = NULL;
1393                charger->attr_g.name = str;
1394                charger->attr_g.attrs = charger->attrs;
1395
1396                sysfs_attr_init(&charger->attr_name.attr);
1397                charger->attr_name.attr.name = "name";
1398                charger->attr_name.attr.mode = 0444;
1399                charger->attr_name.show = charger_name_show;
1400
1401                sysfs_attr_init(&charger->attr_state.attr);
1402                charger->attr_state.attr.name = "state";
1403                charger->attr_state.attr.mode = 0444;
1404                charger->attr_state.show = charger_state_show;
1405
1406                sysfs_attr_init(&charger->attr_externally_control.attr);
1407                charger->attr_externally_control.attr.name
1408                                = "externally_control";
1409                charger->attr_externally_control.attr.mode = 0644;
1410                charger->attr_externally_control.show
1411                                = charger_externally_control_show;
1412                charger->attr_externally_control.store
1413                                = charger_externally_control_store;
1414
1415                if (!desc->charger_regulators[i].externally_control ||
1416                                !chargers_externally_control)
1417                        chargers_externally_control = 0;
1418
1419                dev_info(cm->dev, "'%s' regulator's externally_control is %d\n",
1420                         charger->regulator_name, charger->externally_control);
1421
1422                ret = sysfs_create_group(&cm->charger_psy->dev.kobj,
1423                                        &charger->attr_g);
1424                if (ret < 0) {
1425                        dev_err(cm->dev, "Cannot create sysfs entry of %s regulator\n",
1426                                charger->regulator_name);
1427                        return ret;
1428                }
1429        }
1430
1431        if (chargers_externally_control) {
1432                dev_err(cm->dev, "Cannot register regulator because charger-manager must need at least one charger for charging battery\n");
1433                return -EINVAL;
1434        }
1435
1436        return 0;
1437}
1438
1439static int cm_init_thermal_data(struct charger_manager *cm,
1440                struct power_supply *fuel_gauge)
1441{
1442        struct charger_desc *desc = cm->desc;
1443        union power_supply_propval val;
1444        int ret;
1445
1446        /* Verify whether fuel gauge provides battery temperature */
1447        ret = power_supply_get_property(fuel_gauge,
1448                                        POWER_SUPPLY_PROP_TEMP, &val);
1449
1450        if (!ret) {
1451                cm->charger_psy_desc.properties[cm->charger_psy_desc.num_properties] =
1452                                POWER_SUPPLY_PROP_TEMP;
1453                cm->charger_psy_desc.num_properties++;
1454                cm->desc->measure_battery_temp = true;
1455        }
1456#ifdef CONFIG_THERMAL
1457        if (ret && desc->thermal_zone) {
1458                cm->tzd_batt =
1459                        thermal_zone_get_zone_by_name(desc->thermal_zone);
1460                if (IS_ERR(cm->tzd_batt))
1461                        return PTR_ERR(cm->tzd_batt);
1462
1463                /* Use external thermometer */
1464                cm->charger_psy_desc.properties[cm->charger_psy_desc.num_properties] =
1465                                POWER_SUPPLY_PROP_TEMP_AMBIENT;
1466                cm->charger_psy_desc.num_properties++;
1467                cm->desc->measure_battery_temp = true;
1468                ret = 0;
1469        }
1470#endif
1471        if (cm->desc->measure_battery_temp) {
1472                /* NOTICE : Default allowable minimum charge temperature is 0 */
1473                if (!desc->temp_max)
1474                        desc->temp_max = CM_DEFAULT_CHARGE_TEMP_MAX;
1475                if (!desc->temp_diff)
1476                        desc->temp_diff = CM_DEFAULT_RECHARGE_TEMP_DIFF;
1477        }
1478
1479        return ret;
1480}
1481
1482static const struct of_device_id charger_manager_match[] = {
1483        {
1484                .compatible = "charger-manager",
1485        },
1486        {},
1487};
1488
1489static struct charger_desc *of_cm_parse_desc(struct device *dev)
1490{
1491        struct charger_desc *desc;
1492        struct device_node *np = dev->of_node;
1493        u32 poll_mode = CM_POLL_DISABLE;
1494        u32 battery_stat = CM_NO_BATTERY;
1495        int num_chgs = 0;
1496
1497        desc = devm_kzalloc(dev, sizeof(*desc), GFP_KERNEL);
1498        if (!desc)
1499                return ERR_PTR(-ENOMEM);
1500
1501        of_property_read_string(np, "cm-name", &desc->psy_name);
1502
1503        of_property_read_u32(np, "cm-poll-mode", &poll_mode);
1504        desc->polling_mode = poll_mode;
1505
1506        of_property_read_u32(np, "cm-poll-interval",
1507                                &desc->polling_interval_ms);
1508
1509        of_property_read_u32(np, "cm-fullbatt-vchkdrop-ms",
1510                                        &desc->fullbatt_vchkdrop_ms);
1511        of_property_read_u32(np, "cm-fullbatt-vchkdrop-volt",
1512                                        &desc->fullbatt_vchkdrop_uV);
1513        of_property_read_u32(np, "cm-fullbatt-voltage", &desc->fullbatt_uV);
1514        of_property_read_u32(np, "cm-fullbatt-soc", &desc->fullbatt_soc);
1515        of_property_read_u32(np, "cm-fullbatt-capacity",
1516                                        &desc->fullbatt_full_capacity);
1517
1518        of_property_read_u32(np, "cm-battery-stat", &battery_stat);
1519        desc->battery_present = battery_stat;
1520
1521        /* chargers */
1522        of_property_read_u32(np, "cm-num-chargers", &num_chgs);
1523        if (num_chgs) {
1524                /* Allocate empty bin at the tail of array */
1525                desc->psy_charger_stat = devm_kzalloc(dev, sizeof(char *)
1526                                                * (num_chgs + 1), GFP_KERNEL);
1527                if (desc->psy_charger_stat) {
1528                        int i;
1529                        for (i = 0; i < num_chgs; i++)
1530                                of_property_read_string_index(np, "cm-chargers",
1531                                                i, &desc->psy_charger_stat[i]);
1532                } else {
1533                        return ERR_PTR(-ENOMEM);
1534                }
1535        }
1536
1537        of_property_read_string(np, "cm-fuel-gauge", &desc->psy_fuel_gauge);
1538
1539        of_property_read_string(np, "cm-thermal-zone", &desc->thermal_zone);
1540
1541        of_property_read_u32(np, "cm-battery-cold", &desc->temp_min);
1542        if (of_get_property(np, "cm-battery-cold-in-minus", NULL))
1543                desc->temp_min *= -1;
1544        of_property_read_u32(np, "cm-battery-hot", &desc->temp_max);
1545        of_property_read_u32(np, "cm-battery-temp-diff", &desc->temp_diff);
1546
1547        of_property_read_u32(np, "cm-charging-max",
1548                                &desc->charging_max_duration_ms);
1549        of_property_read_u32(np, "cm-discharging-max",
1550                                &desc->discharging_max_duration_ms);
1551
1552        /* battery charger regualtors */
1553        desc->num_charger_regulators = of_get_child_count(np);
1554        if (desc->num_charger_regulators) {
1555                struct charger_regulator *chg_regs;
1556                struct device_node *child;
1557
1558                chg_regs = devm_kzalloc(dev, sizeof(*chg_regs)
1559                                        * desc->num_charger_regulators,
1560                                        GFP_KERNEL);
1561                if (!chg_regs)
1562                        return ERR_PTR(-ENOMEM);
1563
1564                desc->charger_regulators = chg_regs;
1565
1566                for_each_child_of_node(np, child) {
1567                        struct charger_cable *cables;
1568                        struct device_node *_child;
1569
1570                        of_property_read_string(child, "cm-regulator-name",
1571                                        &chg_regs->regulator_name);
1572
1573                        /* charger cables */
1574                        chg_regs->num_cables = of_get_child_count(child);
1575                        if (chg_regs->num_cables) {
1576                                cables = devm_kzalloc(dev, sizeof(*cables)
1577                                                * chg_regs->num_cables,
1578                                                GFP_KERNEL);
1579                                if (!cables) {
1580                                        of_node_put(child);
1581                                        return ERR_PTR(-ENOMEM);
1582                                }
1583
1584                                chg_regs->cables = cables;
1585
1586                                for_each_child_of_node(child, _child) {
1587                                        of_property_read_string(_child,
1588                                        "cm-cable-name", &cables->name);
1589                                        of_property_read_string(_child,
1590                                        "cm-cable-extcon",
1591                                        &cables->extcon_name);
1592                                        of_property_read_u32(_child,
1593                                        "cm-cable-min",
1594                                        &cables->min_uA);
1595                                        of_property_read_u32(_child,
1596                                        "cm-cable-max",
1597                                        &cables->max_uA);
1598                                        cables++;
1599                                }
1600                        }
1601                        chg_regs++;
1602                }
1603        }
1604        return desc;
1605}
1606
1607static inline struct charger_desc *cm_get_drv_data(struct platform_device *pdev)
1608{
1609        if (pdev->dev.of_node)
1610                return of_cm_parse_desc(&pdev->dev);
1611        return dev_get_platdata(&pdev->dev);
1612}
1613
1614static enum alarmtimer_restart cm_timer_func(struct alarm *alarm, ktime_t now)
1615{
1616        cm_timer_set = false;
1617        return ALARMTIMER_NORESTART;
1618}
1619
1620static int charger_manager_probe(struct platform_device *pdev)
1621{
1622        struct charger_desc *desc = cm_get_drv_data(pdev);
1623        struct charger_manager *cm;
1624        int ret, i = 0;
1625        int j = 0;
1626        union power_supply_propval val;
1627        struct power_supply *fuel_gauge;
1628        struct power_supply_config psy_cfg = {};
1629
1630        if (IS_ERR(desc)) {
1631                dev_err(&pdev->dev, "No platform data (desc) found\n");
1632                return -ENODEV;
1633        }
1634
1635        cm = devm_kzalloc(&pdev->dev, sizeof(*cm), GFP_KERNEL);
1636        if (!cm)
1637                return -ENOMEM;
1638
1639        /* Basic Values. Unspecified are Null or 0 */
1640        cm->dev = &pdev->dev;
1641        cm->desc = desc;
1642        psy_cfg.drv_data = cm;
1643
1644        /* Initialize alarm timer */
1645        if (alarmtimer_get_rtcdev()) {
1646                cm_timer = devm_kzalloc(cm->dev, sizeof(*cm_timer), GFP_KERNEL);
1647                if (!cm_timer)
1648                        return -ENOMEM;
1649                alarm_init(cm_timer, ALARM_BOOTTIME, cm_timer_func);
1650        }
1651
1652        /*
1653         * Some of the following do not need to be errors.
1654         * Users may intentionally ignore those features.
1655         */
1656        if (desc->fullbatt_uV == 0) {
1657                dev_info(&pdev->dev, "Ignoring full-battery voltage threshold as it is not supplied\n");
1658        }
1659        if (!desc->fullbatt_vchkdrop_ms || !desc->fullbatt_vchkdrop_uV) {
1660                dev_info(&pdev->dev, "Disabling full-battery voltage drop checking mechanism as it is not supplied\n");
1661                desc->fullbatt_vchkdrop_ms = 0;
1662                desc->fullbatt_vchkdrop_uV = 0;
1663        }
1664        if (desc->fullbatt_soc == 0) {
1665                dev_info(&pdev->dev, "Ignoring full-battery soc(state of charge) threshold as it is not supplied\n");
1666        }
1667        if (desc->fullbatt_full_capacity == 0) {
1668                dev_info(&pdev->dev, "Ignoring full-battery full capacity threshold as it is not supplied\n");
1669        }
1670
1671        if (!desc->charger_regulators || desc->num_charger_regulators < 1) {
1672                dev_err(&pdev->dev, "charger_regulators undefined\n");
1673                return -EINVAL;
1674        }
1675
1676        if (!desc->psy_charger_stat || !desc->psy_charger_stat[0]) {
1677                dev_err(&pdev->dev, "No power supply defined\n");
1678                return -EINVAL;
1679        }
1680
1681        if (!desc->psy_fuel_gauge) {
1682                dev_err(&pdev->dev, "No fuel gauge power supply defined\n");
1683                return -EINVAL;
1684        }
1685
1686        /* Counting index only */
1687        while (desc->psy_charger_stat[i])
1688                i++;
1689
1690        /* Check if charger's supplies are present at probe */
1691        for (i = 0; desc->psy_charger_stat[i]; i++) {
1692                struct power_supply *psy;
1693
1694                psy = power_supply_get_by_name(desc->psy_charger_stat[i]);
1695                if (!psy) {
1696                        dev_err(&pdev->dev, "Cannot find power supply \"%s\"\n",
1697                                desc->psy_charger_stat[i]);
1698                        return -ENODEV;
1699                }
1700                power_supply_put(psy);
1701        }
1702
1703        if (desc->polling_interval_ms == 0 ||
1704            msecs_to_jiffies(desc->polling_interval_ms) <= CM_JIFFIES_SMALL) {
1705                dev_err(&pdev->dev, "polling_interval_ms is too small\n");
1706                return -EINVAL;
1707        }
1708
1709        if (!desc->charging_max_duration_ms ||
1710                        !desc->discharging_max_duration_ms) {
1711                dev_info(&pdev->dev, "Cannot limit charging duration checking mechanism to prevent overcharge/overheat and control discharging duration\n");
1712                desc->charging_max_duration_ms = 0;
1713                desc->discharging_max_duration_ms = 0;
1714        }
1715
1716        platform_set_drvdata(pdev, cm);
1717
1718        memcpy(&cm->charger_psy_desc, &psy_default, sizeof(psy_default));
1719
1720        if (!desc->psy_name)
1721                strncpy(cm->psy_name_buf, psy_default.name, PSY_NAME_MAX);
1722        else
1723                strncpy(cm->psy_name_buf, desc->psy_name, PSY_NAME_MAX);
1724        cm->charger_psy_desc.name = cm->psy_name_buf;
1725
1726        /* Allocate for psy properties because they may vary */
1727        cm->charger_psy_desc.properties = devm_kzalloc(&pdev->dev,
1728                                sizeof(enum power_supply_property)
1729                                * (ARRAY_SIZE(default_charger_props) +
1730                                NUM_CHARGER_PSY_OPTIONAL), GFP_KERNEL);
1731        if (!cm->charger_psy_desc.properties)
1732                return -ENOMEM;
1733
1734        memcpy(cm->charger_psy_desc.properties, default_charger_props,
1735                sizeof(enum power_supply_property) *
1736                ARRAY_SIZE(default_charger_props));
1737        cm->charger_psy_desc.num_properties = psy_default.num_properties;
1738
1739        /* Find which optional psy-properties are available */
1740        fuel_gauge = power_supply_get_by_name(desc->psy_fuel_gauge);
1741        if (!fuel_gauge) {
1742                dev_err(&pdev->dev, "Cannot find power supply \"%s\"\n",
1743                        desc->psy_fuel_gauge);
1744                return -ENODEV;
1745        }
1746        if (!power_supply_get_property(fuel_gauge,
1747                                          POWER_SUPPLY_PROP_CHARGE_NOW, &val)) {
1748                cm->charger_psy_desc.properties[cm->charger_psy_desc.num_properties] =
1749                                POWER_SUPPLY_PROP_CHARGE_NOW;
1750                cm->charger_psy_desc.num_properties++;
1751        }
1752        if (!power_supply_get_property(fuel_gauge,
1753                                          POWER_SUPPLY_PROP_CURRENT_NOW,
1754                                          &val)) {
1755                cm->charger_psy_desc.properties[cm->charger_psy_desc.num_properties] =
1756                                POWER_SUPPLY_PROP_CURRENT_NOW;
1757                cm->charger_psy_desc.num_properties++;
1758        }
1759
1760        ret = cm_init_thermal_data(cm, fuel_gauge);
1761        if (ret) {
1762                dev_err(&pdev->dev, "Failed to initialize thermal data\n");
1763                cm->desc->measure_battery_temp = false;
1764        }
1765        power_supply_put(fuel_gauge);
1766
1767        INIT_DELAYED_WORK(&cm->fullbatt_vchk_work, fullbatt_vchk);
1768
1769        cm->charger_psy = power_supply_register(&pdev->dev,
1770                                                &cm->charger_psy_desc,
1771                                                &psy_cfg);
1772        if (IS_ERR(cm->charger_psy)) {
1773                dev_err(&pdev->dev, "Cannot register charger-manager with name \"%s\"\n",
1774                        cm->charger_psy_desc.name);
1775                return PTR_ERR(cm->charger_psy);
1776        }
1777
1778        /* Register extcon device for charger cable */
1779        ret = charger_manager_register_extcon(cm);
1780        if (ret < 0) {
1781                dev_err(&pdev->dev, "Cannot initialize extcon device\n");
1782                goto err_reg_extcon;
1783        }
1784
1785        /* Register sysfs entry for charger(regulator) */
1786        ret = charger_manager_register_sysfs(cm);
1787        if (ret < 0) {
1788                dev_err(&pdev->dev,
1789                        "Cannot initialize sysfs entry of regulator\n");
1790                goto err_reg_sysfs;
1791        }
1792
1793        /* Add to the list */
1794        mutex_lock(&cm_list_mtx);
1795        list_add(&cm->entry, &cm_list);
1796        mutex_unlock(&cm_list_mtx);
1797
1798        /*
1799         * Charger-manager is capable of waking up the systme from sleep
1800         * when event is happend through cm_notify_event()
1801         */
1802        device_init_wakeup(&pdev->dev, true);
1803        device_set_wakeup_capable(&pdev->dev, false);
1804
1805        /*
1806         * Charger-manager have to check the charging state right after
1807         * tialization of charger-manager and then update current charging
1808         * state.
1809         */
1810        cm_monitor();
1811
1812        schedule_work(&setup_polling);
1813
1814        return 0;
1815
1816err_reg_sysfs:
1817        for (i = 0; i < desc->num_charger_regulators; i++) {
1818                struct charger_regulator *charger;
1819
1820                charger = &desc->charger_regulators[i];
1821                sysfs_remove_group(&cm->charger_psy->dev.kobj,
1822                                &charger->attr_g);
1823        }
1824err_reg_extcon:
1825        for (i = 0; i < desc->num_charger_regulators; i++) {
1826                struct charger_regulator *charger;
1827
1828                charger = &desc->charger_regulators[i];
1829                for (j = 0; j < charger->num_cables; j++) {
1830                        struct charger_cable *cable = &charger->cables[j];
1831                        /* Remove notifier block if only edev exists */
1832                        if (cable->extcon_dev.edev)
1833                                extcon_unregister_interest(&cable->extcon_dev);
1834                }
1835
1836                regulator_put(desc->charger_regulators[i].consumer);
1837        }
1838
1839        power_supply_unregister(cm->charger_psy);
1840
1841        return ret;
1842}
1843
1844static int charger_manager_remove(struct platform_device *pdev)
1845{
1846        struct charger_manager *cm = platform_get_drvdata(pdev);
1847        struct charger_desc *desc = cm->desc;
1848        int i = 0;
1849        int j = 0;
1850
1851        /* Remove from the list */
1852        mutex_lock(&cm_list_mtx);
1853        list_del(&cm->entry);
1854        mutex_unlock(&cm_list_mtx);
1855
1856        cancel_work_sync(&setup_polling);
1857        cancel_delayed_work_sync(&cm_monitor_work);
1858
1859        for (i = 0 ; i < desc->num_charger_regulators ; i++) {
1860                struct charger_regulator *charger
1861                                = &desc->charger_regulators[i];
1862                for (j = 0 ; j < charger->num_cables ; j++) {
1863                        struct charger_cable *cable = &charger->cables[j];
1864                        extcon_unregister_interest(&cable->extcon_dev);
1865                }
1866        }
1867
1868        for (i = 0 ; i < desc->num_charger_regulators ; i++)
1869                regulator_put(desc->charger_regulators[i].consumer);
1870
1871        power_supply_unregister(cm->charger_psy);
1872
1873        try_charger_enable(cm, false);
1874
1875        return 0;
1876}
1877
1878static const struct platform_device_id charger_manager_id[] = {
1879        { "charger-manager", 0 },
1880        { },
1881};
1882MODULE_DEVICE_TABLE(platform, charger_manager_id);
1883
1884static int cm_suspend_noirq(struct device *dev)
1885{
1886        if (device_may_wakeup(dev)) {
1887                device_set_wakeup_capable(dev, false);
1888                return -EAGAIN;
1889        }
1890
1891        return 0;
1892}
1893
1894static bool cm_need_to_awake(void)
1895{
1896        struct charger_manager *cm;
1897
1898        if (cm_timer)
1899                return false;
1900
1901        mutex_lock(&cm_list_mtx);
1902        list_for_each_entry(cm, &cm_list, entry) {
1903                if (is_charging(cm)) {
1904                        mutex_unlock(&cm_list_mtx);
1905                        return true;
1906                }
1907        }
1908        mutex_unlock(&cm_list_mtx);
1909
1910        return false;
1911}
1912
1913static int cm_suspend_prepare(struct device *dev)
1914{
1915        struct charger_manager *cm = dev_get_drvdata(dev);
1916
1917        if (cm_need_to_awake())
1918                return -EBUSY;
1919
1920        if (!cm_suspended)
1921                cm_suspended = true;
1922
1923        cm_timer_set = cm_setup_timer();
1924
1925        if (cm_timer_set) {
1926                cancel_work_sync(&setup_polling);
1927                cancel_delayed_work_sync(&cm_monitor_work);
1928                cancel_delayed_work(&cm->fullbatt_vchk_work);
1929        }
1930
1931        return 0;
1932}
1933
1934static void cm_suspend_complete(struct device *dev)
1935{
1936        struct charger_manager *cm = dev_get_drvdata(dev);
1937
1938        if (cm_suspended)
1939                cm_suspended = false;
1940
1941        if (cm_timer_set) {
1942                ktime_t remain;
1943
1944                alarm_cancel(cm_timer);
1945                cm_timer_set = false;
1946                remain = alarm_expires_remaining(cm_timer);
1947                cm_suspend_duration_ms -= ktime_to_ms(remain);
1948                schedule_work(&setup_polling);
1949        }
1950
1951        _cm_monitor(cm);
1952
1953        /* Re-enqueue delayed work (fullbatt_vchk_work) */
1954        if (cm->fullbatt_vchk_jiffies_at) {
1955                unsigned long delay = 0;
1956                unsigned long now = jiffies + CM_JIFFIES_SMALL;
1957
1958                if (time_after_eq(now, cm->fullbatt_vchk_jiffies_at)) {
1959                        delay = (unsigned long)((long)now
1960                                - (long)(cm->fullbatt_vchk_jiffies_at));
1961                        delay = jiffies_to_msecs(delay);
1962                } else {
1963                        delay = 0;
1964                }
1965
1966                /*
1967                 * Account for cm_suspend_duration_ms with assuming that
1968                 * timer stops in suspend.
1969                 */
1970                if (delay > cm_suspend_duration_ms)
1971                        delay -= cm_suspend_duration_ms;
1972                else
1973                        delay = 0;
1974
1975                queue_delayed_work(cm_wq, &cm->fullbatt_vchk_work,
1976                                   msecs_to_jiffies(delay));
1977        }
1978        device_set_wakeup_capable(cm->dev, false);
1979}
1980
1981static const struct dev_pm_ops charger_manager_pm = {
1982        .prepare        = cm_suspend_prepare,
1983        .suspend_noirq  = cm_suspend_noirq,
1984        .complete       = cm_suspend_complete,
1985};
1986
1987static struct platform_driver charger_manager_driver = {
1988        .driver = {
1989                .name = "charger-manager",
1990                .pm = &charger_manager_pm,
1991                .of_match_table = charger_manager_match,
1992        },
1993        .probe = charger_manager_probe,
1994        .remove = charger_manager_remove,
1995        .id_table = charger_manager_id,
1996};
1997
1998static int __init charger_manager_init(void)
1999{
2000        cm_wq = create_freezable_workqueue("charger_manager");
2001        INIT_DELAYED_WORK(&cm_monitor_work, cm_monitor_poller);
2002
2003        return platform_driver_register(&charger_manager_driver);
2004}
2005late_initcall(charger_manager_init);
2006
2007static void __exit charger_manager_cleanup(void)
2008{
2009        destroy_workqueue(cm_wq);
2010        cm_wq = NULL;
2011
2012        platform_driver_unregister(&charger_manager_driver);
2013}
2014module_exit(charger_manager_cleanup);
2015
2016/**
2017 * cm_notify_event - charger driver notify Charger Manager of charger event
2018 * @psy: pointer to instance of charger's power_supply
2019 * @type: type of charger event
2020 * @msg: optional message passed to uevent_notify fuction
2021 */
2022void cm_notify_event(struct power_supply *psy, enum cm_event_types type,
2023                     char *msg)
2024{
2025        struct charger_manager *cm;
2026        bool found_power_supply = false;
2027
2028        if (psy == NULL)
2029                return;
2030
2031        mutex_lock(&cm_list_mtx);
2032        list_for_each_entry(cm, &cm_list, entry) {
2033                if (match_string(cm->desc->psy_charger_stat, -1,
2034                                 psy->desc->name) >= 0) {
2035                        found_power_supply = true;
2036                        break;
2037                }
2038        }
2039        mutex_unlock(&cm_list_mtx);
2040
2041        if (!found_power_supply)
2042                return;
2043
2044        switch (type) {
2045        case CM_EVENT_BATT_FULL:
2046                fullbatt_handler(cm);
2047                break;
2048        case CM_EVENT_BATT_OUT:
2049                battout_handler(cm);
2050                break;
2051        case CM_EVENT_BATT_IN:
2052        case CM_EVENT_EXT_PWR_IN_OUT ... CM_EVENT_CHG_START_STOP:
2053                misc_event_handler(cm, type);
2054                break;
2055        case CM_EVENT_UNKNOWN:
2056        case CM_EVENT_OTHERS:
2057                uevent_notify(cm, msg ? msg : default_event_names[type]);
2058                break;
2059        default:
2060                dev_err(cm->dev, "%s: type not specified\n", __func__);
2061                break;
2062        }
2063}
2064EXPORT_SYMBOL_GPL(cm_notify_event);
2065
2066MODULE_AUTHOR("MyungJoo Ham <myungjoo.ham@samsung.com>");
2067MODULE_DESCRIPTION("Charger Manager");
2068MODULE_LICENSE("GPL");
2069