linux/Documentation/hwmon/sht3x.rst
<<
>>
Prefs
   1Kernel driver sht3x
   2===================
   3
   4Supported chips:
   5
   6  * Sensirion SHT3x-DIS
   7
   8    Prefix: 'sht3x'
   9
  10    Addresses scanned: none
  11
  12    Datasheet: https://www.sensirion.com/file/datasheet_sht3x_digital
  13
  14Author:
  15
  16  - David Frey <david.frey@sensirion.com>
  17  - Pascal Sachs <pascal.sachs@sensirion.com>
  18
  19Description
  20-----------
  21
  22This driver implements support for the Sensirion SHT3x-DIS chip, a humidity
  23and temperature sensor. Temperature is measured in degrees celsius, relative
  24humidity is expressed as a percentage. In the sysfs interface, all values are
  25scaled by 1000, i.e. the value for 31.5 degrees celsius is 31500.
  26
  27The device communicates with the I2C protocol. Sensors can have the I2C
  28addresses 0x44 or 0x45, depending on the wiring. See
  29Documentation/i2c/instantiating-devices.rst for methods to instantiate the device.
  30
  31There are two options configurable by means of sht3x_platform_data:
  32
  331. blocking (pull the I2C clock line down while performing the measurement) or
  34   non-blocking mode. Blocking mode will guarantee the fastest result but
  35   the I2C bus will be busy during that time. By default, non-blocking mode
  36   is used. Make sure clock-stretching works properly on your device if you
  37   want to use blocking mode.
  382. high or low accuracy. High accuracy is used by default and using it is
  39   strongly recommended.
  40
  41The sht3x sensor supports a single shot mode as well as 5 periodic measure
  42modes, which can be controlled with the update_interval sysfs interface.
  43The allowed update_interval in milliseconds are as follows:
  44
  45    ===== ======= ====================
  46       0          single shot mode
  47    2000   0.5 Hz periodic measurement
  48    1000   1   Hz periodic measurement
  49     500   2   Hz periodic measurement
  50     250   4   Hz periodic measurement
  51     100  10   Hz periodic measurement
  52    ===== ======= ====================
  53
  54In the periodic measure mode, the sensor automatically triggers a measurement
  55with the configured update interval on the chip. When a temperature or humidity
  56reading exceeds the configured limits, the alert attribute is set to 1 and
  57the alert pin on the sensor is set to high.
  58When the temperature and humidity readings move back between the hysteresis
  59values, the alert bit is set to 0 and the alert pin on the sensor is set to
  60low.
  61
  62sysfs-Interface
  63---------------
  64
  65=================== ============================================================
  66temp1_input:        temperature input
  67humidity1_input:    humidity input
  68temp1_max:          temperature max value
  69temp1_max_hyst:     temperature hysteresis value for max limit
  70humidity1_max:      humidity max value
  71humidity1_max_hyst: humidity hysteresis value for max limit
  72temp1_min:          temperature min value
  73temp1_min_hyst:     temperature hysteresis value for min limit
  74humidity1_min:      humidity min value
  75humidity1_min_hyst: humidity hysteresis value for min limit
  76temp1_alarm:        alarm flag is set to 1 if the temperature is outside the
  77                    configured limits. Alarm only works in periodic measure mode
  78humidity1_alarm:    alarm flag is set to 1 if the humidity is outside the
  79                    configured limits. Alarm only works in periodic measure mode
  80heater_enable:      heater enable, heating element removes excess humidity from
  81                    sensor:
  82
  83                        - 0: turned off
  84                        - 1: turned on
  85update_interval:    update interval, 0 for single shot, interval in msec
  86                    for periodic measurement. If the interval is not supported
  87                    by the sensor, the next faster interval is chosen